Vinyl Windows and Doors
Part Number: V983492
© 2010 Pella Corporation
INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION
350 SERIES O,OX/XO SLIDINg PATIO DOOR
WITh fIXED PANEL INSTALLED
Lea las instrucciones en español en el reverso.
Table Of Contents
Installation Instruction Information ...........................................................................................Page-1
Exploded View of Installation and Parts List ............................................................................Page-2
Step 1: Rough Opening Preparation ........................................................................................Page-3
Step 3: Setting and Fastening the Door ..................................................................................Page-4
Step 2: Prepare the Door for Installation .................................................................................Page-4
Step 4: Reinstall the Sliding Panel ............................................................................................Page-7
Step 5: Integrating the Door to the Water Resistive Barrier .................................................Page-8
Step 6: Interior Seal ....................................................................................................................Page-8
Step 7: Sealing the Door to the Exterior Wall Cladding .......................................................Page-9
Step 8: Flush Flange Opening Preparation .......................................................................... Page-11
Step 9: Setting and Fastening the Door in Flush Flange Applications ............................. Page-13
Step 10: Optional Sill Pan Fabrication and Installation ....................................................... Page-15
Cleaning Instructions and Important Notice Preparation ................................................... Page-16
Installation Instructions for Typical Wood frame Construction and Concrete Block
Constructions.
These instructions were developed and tested for use with typical wood frame wall and concrete
block constructions in a wall system designed to manage water. Installation details specific to
replacement of Aluminum Sliding Doors in Hard Coat Stucco applications can be found at the end
of this instruction. These instructions are not to be used with any other construction method.
Installation instructions for use with other construction methods or multiple units may be obtained
from Pella Corporation or local Pella retailer. Building designs, construction methods, building
materials, and site conditions unique to your project may require an installation method different
from these instructions and additional care. Determining the appropriate installation method is the
responsibility of you, your architect, or construction professional.
The performance of any building is dependent upon the design, installation, and
workmanship of the entire building system. Pella Corporation strongly recommends consulting
an experienced architect, contractor, or structural engineer prior to installation of Pella products.
The individual (building owner, architect, contractor, installer and/or consumer) responsible for the
project must take into account local conditions, building codes, inherent component limitations,
the effects of aging and weathering on building components, and other design issues relevant
to each project. The determination of the suitability of all building components for each project,
as well as the design and installation of flashing and sealing systems, are the responsibility of the
building owner, architect, contractor, installer and/or consumer
Handling and Storage: Provide full support under the framework while storing, moving and
installing the product. DO NOT lift the product by the head member only. Remove the plastic
shipping material prior to storing or installing the product. DO NOT store in direct sunlight. Allow
sufficient spacing between products for ventilation