Pantech GF Series User Manual
Page 4
GF Specifications
GF-200
GF-300
GF-1200
GF-2000
GF-3000
GF-6000
Weighing Capacity
Resolution
Repeatability
Linearity
Stabilization time
Sensoring method
Display type
Sensitivity drift
(10° C to 30° C/50° F to 80° F)
Counting Mimimum unit mass
mode
Number of samples
Percent
Minimum 100% reference mass
mode
Minimum 100% display
Weighing units & modes
Display refresh rate
Operating environment temperature
External dimensions
AC adapter
Power consumption
Standard serial I/F
External calibration weight to be used
Weighing pan
Net weight
210g
310 g
1210g
2100g
3100g
6100g
0.001g
0.01g
0.1g
0.001g
0.01g
0.1g
±0.002g
±0.02g
±0.1g
Approx. one second (Typ. FAST response setting)
Super Hybrid Sensor (SHS)
Vacuum Fluorescent Display (VFD)
± 2ppm/°C
± 5ppm/°C
0.001g
0.01g
0.1g
5, 10, 25, 50 or 100 pieces
0.100g
1.00g
10.0g
0.01%, 0.1%, 1% (depends on reference mass stored)
g, PC, PCT, OZ, Lb, L Oz, Ozt, ct, mm, dwt, GN, TL, DS, Mit, newtons
5 times / second or 10 times / second
5° C to 40° C (41° F to 104° F), 85 % RH or less (No condensation)
210 (W) x 317 (D) x 86 (H) mm
Confirm that the adapter type is correct for the local voltage and power receptade
Approx. 11VA (supplied by AC adapter)
RS-232C interface with WinCT (WinCT: included as CD-ROM)
200g
300g
1000g
2000g
3000g
6000g
100g
200g
500g
1000g
2000g
5000g
100g
1000g
4000g
3000g
2000g
128 x 128 mm
165 x 165 mm
Approx. 3.8kg
Approx. 4.3kg
GX
Specifications
GX-200-EC GX-400-EC
GX-600-EC GX-2000-EC GX-4000-EC GX-6100-EC GX-6000-EC GX-8000-EC
Weighing Capacity (Max)
Resolution (d)
Repeatability
Linearity
Stabilization time
Sensoring method
Display type
Sensitivity drift
(10° C to 30° C/50° F to 86° F)
Counting Mimimum unit mass
mode
Number of samples
Percent
Minimum 100% reference mass
mode
Minimum 100% display
Weighing units & modes
Display refresh rate
Operating environment temperature
External dimensions
AC adapter
Power consumption
Standard serial I/F
External calibration weight to be used
Calibration
Net weight
210g
410 g
610g
2100g
4100g
6100g
6100g
8100g
0.001g
0.01g
0.1g
0.001g
0.01g
0.1g
±0.002g
±0.003g
±0.02g
±0.03g
±0.1g
Approx. 1 second
Approx. 1.5 s
Approx. 1 second
Super Hybrid Sensor (SHS)
Vacuum Fluorescent Display (VFD)
± 2ppm/°C (When automatic self calibration is not used)
± 5ppm/°C (auto-self calibration OFF)
0.001g
0.01g
0.1g
5, 10, 25, 50 or 100 pieces
0.100g
1.00g
10.0g
0.01%, 0.1%, 1% (depends on reference mass stored)
g, PC, PCT, OZ, Lb, L Oz, Ozt, ct, mm, dwt, GN, TL, DS, Mit, newtons
5 times / second or 10 times / second
5° C to 40° C (41° F to 104° F), 85 % RH or less (No condensation)
210 (W) x 317 (D) x 86 (H) mm
Confirm that the adapter type is correct for the local voltage and power receptade
Approx. 11VA (supplied by AC adapter)
RS-232C interface with WinCT (WinCT: included as CD-ROM)
200g
400g
600g
2000g
4000g
6000g
6000g
8000g
100g
300g
500g
1000g
3000g
5000g
5000g
7000g
200g
400g
2000g
4000g
4000g
6000g
300g
3000g
3000g
5000g
4000g
Motor-driven internal calibration with SHS
Approx. 4.6kg
Approx. 5.1kg