Pantech GF Series User Manual

Page 4

background image

GF Specifications

GF-200

GF-300

GF-1200

GF-2000

GF-3000

GF-6000

Weighing Capacity

Resolution

Repeatability

Linearity

Stabilization time

Sensoring method

Display type

Sensitivity drift

(10° C to 30° C/50° F to 80° F)

Counting Mimimum unit mass

mode

Number of samples

Percent

Minimum 100% reference mass

mode

Minimum 100% display

Weighing units & modes

Display refresh rate

Operating environment temperature

External dimensions

AC adapter

Power consumption

Standard serial I/F

External calibration weight to be used

Weighing pan

Net weight

210g

310 g

1210g

2100g

3100g

6100g

0.001g

0.01g

0.1g

0.001g

0.01g

0.1g

±0.002g

±0.02g

±0.1g

Approx. one second (Typ. FAST response setting)

Super Hybrid Sensor (SHS)

Vacuum Fluorescent Display (VFD)

± 2ppm/°C

± 5ppm/°C

0.001g

0.01g

0.1g

5, 10, 25, 50 or 100 pieces

0.100g

1.00g

10.0g

0.01%, 0.1%, 1% (depends on reference mass stored)

g, PC, PCT, OZ, Lb, L Oz, Ozt, ct, mm, dwt, GN, TL, DS, Mit, newtons

5 times / second or 10 times / second

5° C to 40° C (41° F to 104° F), 85 % RH or less (No condensation)

210 (W) x 317 (D) x 86 (H) mm

Confirm that the adapter type is correct for the local voltage and power receptade

Approx. 11VA (supplied by AC adapter)

RS-232C interface with WinCT (WinCT: included as CD-ROM)

200g

300g

1000g

2000g

3000g

6000g

100g

200g

500g

1000g

2000g

5000g

100g

1000g

4000g

3000g

2000g

128 x 128 mm

165 x 165 mm

Approx. 3.8kg

Approx. 4.3kg

GX

Specifications

GX-200-EC GX-400-EC

GX-600-EC GX-2000-EC GX-4000-EC GX-6100-EC GX-6000-EC GX-8000-EC

Weighing Capacity (Max)

Resolution (d)

Repeatability

Linearity

Stabilization time

Sensoring method

Display type

Sensitivity drift

(10° C to 30° C/50° F to 86° F)

Counting Mimimum unit mass

mode

Number of samples

Percent

Minimum 100% reference mass

mode

Minimum 100% display

Weighing units & modes

Display refresh rate

Operating environment temperature

External dimensions

AC adapter

Power consumption

Standard serial I/F

External calibration weight to be used

Calibration

Net weight

210g

410 g

610g

2100g

4100g

6100g

6100g

8100g

0.001g

0.01g

0.1g

0.001g

0.01g

0.1g

±0.002g

±0.003g

±0.02g

±0.03g

±0.1g

Approx. 1 second

Approx. 1.5 s

Approx. 1 second

Super Hybrid Sensor (SHS)

Vacuum Fluorescent Display (VFD)

± 2ppm/°C (When automatic self calibration is not used)

± 5ppm/°C (auto-self calibration OFF)

0.001g

0.01g

0.1g

5, 10, 25, 50 or 100 pieces

0.100g

1.00g

10.0g

0.01%, 0.1%, 1% (depends on reference mass stored)

g, PC, PCT, OZ, Lb, L Oz, Ozt, ct, mm, dwt, GN, TL, DS, Mit, newtons

5 times / second or 10 times / second

5° C to 40° C (41° F to 104° F), 85 % RH or less (No condensation)

210 (W) x 317 (D) x 86 (H) mm

Confirm that the adapter type is correct for the local voltage and power receptade

Approx. 11VA (supplied by AC adapter)

RS-232C interface with WinCT (WinCT: included as CD-ROM)

200g

400g

600g

2000g

4000g

6000g

6000g

8000g

100g

300g

500g

1000g

3000g

5000g

5000g

7000g

200g

400g

2000g

4000g

4000g

6000g

300g

3000g

3000g

5000g

4000g

Motor-driven internal calibration with SHS

Approx. 4.6kg

Approx. 5.1kg