Before Starting

Break-in Procedure

Serious damage may result if the following break-in
instructions are not closely followed.

This procedure is required before the air compressor is put into service and
when the check valve or a complete compressor pump has been replaced.

1. Make sure the On/Auto/Off lever is in the "OFF" position.

2. Check oil level in pump. See "Oil" paragraph in the "Maintenance" section

for instructions.

3. Plug the power cord into the correct branch circuit receptacle. (Refer to

Voltage and Circuit Protection paragraph in the Installation section of this
manual.)

4. Open the drain valve fully (counter-clockwise) to permit air to escape and

prevent air pressure build up in the air tank during the break-in period.

5. Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will

start.

6. Run the compressor for 20 minutes. Make sure the drain valve is open and

there is minimal air pressure build-up in tank.

7. After

20

minutes, close the drain valve (clockwise). The air receiver will fill

to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Risk of bursting. Use a tire pressure gauge to check the
tires pressure before each use and while infl ating tires; see

the tire sidewall for the correct tire pressure.

NOTE: Air tanks, compressors and similar equipment used to infl ate tires can fi ll
small tires similar to these very rapidly. Adjust pressure regulator on air supply to
no more than the rating of the tire pressure. Add air in small increments and
frequently use the tire gauge to prevent over infl ation.

Before Each Start-Up:

1. Place On/Auto/Off lever to "OFF".

2. Pull regulator knob out, turn counter-clockwise until it stops. Push knob in

to lock in place.

3. Attach hose and accessories. NOTE: The hose or accessory will require

a quick connect plug. To use remote console, see "How to Use Remote
Console" paragraph in this section.

Too much air pressure causes a hazardous risk of
bursting. Check the manufacturer’s maximum pressure

rating for air tools and accessories. The regulator outlet pressure must
never exceed the maximum pressure rating.

How to Use Your Unit

How to Stop:

1. Set the On/Auto/Off lever to "OFF".