Glossary, Duty cycle, Specifications – Porter-Cable JOB BOSS C3150 User Manual
Page 8
8- ENG
D28299
GLOSSARY
Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks:
UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent
safety laboratories and meet the applicable Underwriters Laboratories
Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you
continue to use your accessory. When the tank pressure drops to a certain low
level the motor will restart automatically. The low pressure at which the motor
automatically restarts is called “cut-in” pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run,
air pressure in the air tank begins to build. It builds to a certain high pressure
before the motor automatically shuts off - protecting your air tank from
pressure higher than its capacity. The high pressure at which the motor shuts
off is called “cut-out” pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.
DUTY CYCLE
This air compressor pump is capable of running continuously. However, to
prolong the life of your air compressor, it is recommended that a 50%-75%
average duty cycle be maintained; that is, the air compressor pump should not
run more than 30-45 minutes in any given hour.
SPECIFICATIONS
Model No.
C3150
Horsepower Peak
3.5
Bore
2.375"
Stroke
1.350"
*
Voltage-Single Phase
120
* * Minimum Branch Circuit Requirement
15 amps
*
Fuse Type
Time Delay
Air Tank Capacity (Gallon)
4.5
Approximate Cut-in Pressure
120 PSIG
Approximate Cut-out Pressure
150 PSIG
SCFM @ 90 PSIG
6.0
*
This air compressor can be operated on a 15 amp
circuit if:
1.
Voltage supply to circuit is normal.
2.
Circuit is not used to supply any other electrical needs (lights, appliances, etc.)
3.
Extension cords comply with specifications in owners manual.
4.
Circuit is equipped with 15 amp circuit breaker or 15 amp time delay fuse.
If any of the above conditions cannot be met, or if operation of the air compressor
repeatedly causes interruption of the power it may be necessary to operate it from a
20 amp circuit. It is not necessary to change the cord set.
* * A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same
rating as the branch circuit on which the air compressor is operated. If the air
compressor is connected to a circuit protected by fuses, use dual element time
delay fuses.