beautypg.com

1 connecting the twisted-pair line interface, Connecting the twisted-pair line interface, Er to section 3.1 – Patton electronic CopperLINK 2172A User Manual

Page 10: Caution

background image

10

Figure 2.

Model 2172A standalone rear panel

3.1 CONNECTING THE TWISTED-PAIR LINE INTERFACE

The Model 2172A supports communication between two peer Ethernet
LAN sites over a distance of up to 4,250 ft (1.3 km) over 24 AWG
(0.5 mm) twisted-pair wire.

Note

Actual distance and link performance may vary depending on

the environment and type/gauge of wire used.

Follow the steps below to connect the Model 2172A CopperLINK Inter-
faces.

Note

The Model 2172A units work in pairs. One of the units must be

configured as a (L) Local unit, and the other unit must be config-
ured as a (R) Remote unit. It does not matter which end is the L
and which is the R. The link is always initiated by the R unit. As
long as the L unit is powered on, the R unit can establish a link
by being powered on or by having its power reset.

The Interconnecting cables shall be acceptable for
external use and shall be rated for the proper applica-
tion with respect to voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability.

Lin

e

Po

we

r

M

ad

e

in

th

e

US

A

Et

he

rn

et

Power

jack

Dual 10/100

Ethernet ports

CopperLINK

twisted-pair

RJ-45 interface

2

1

CAUTION