beautypg.com

How to use your unit – Porter-Cable N003568 User Manual

Page 11

background image

11 - ENG

N003568

Air Compressor Pump (not shown): Compresses air into the air tank. Working

air is not available until the compressor has raised the air tank pressure above that

required at the air outlet.

Drain Valve: The drain valve is located at the base of the

Drain

Valve

air tank and is used to drain condensation at the end of

each use.

Check Valve: When the air compressor is operating, the

check valve is "open", allowing compressed air to enter

the air tank. When the air compressor reaches "cut-out"

pressure, the check valve "closes", allowing air

Check Valve

pressure to remain inside the air tank.
Motor Overload Protector (not shown): The

motor has an automatic reset thermal overload

protector. If the motor overheats for any reason,

the overload protector will shut off the motor.

The motor must be allowed to cool down before

restarting. The compressor will automatically

restart after the motor cools.

HOW TO USE YOUR UNIT

How to Stop
1. Set the On/Off switch to "Off".
Before Starting

Do not operate this unit until you read and understand this

instruction manual for safety, operation and maintenance

instructions.

Break-in Procedure

Risk of Unsafe Operation. Serious damage may result if the

following break-in instructions are not closely followed.

This procedure is required

before the air compressor is put into service and when

the check valve or a complete compressor pump has been replaced.
1. Make sure the On/Off switch is in the "Off" position.
2. Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage

and Circuit Protection paragraph in the Installation section of this manual.)

3. Open the drain valve (counter-clockwise) fully to permit air to escape and pre-

vent air pressure build up in the air tank during the break-in period.

4. Move the On/Off switch to "On" position. The compressor will start.
5. Run the compressor for 15 minutes. Make sure the drain valve is open and

there is minimal air pressure build-up in tank.

6. After 15 minutes, close the drain valve by turning clockwise. The air receiver

will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.
Before Each Start-Up
1. Set the On/Off switch to "Off".
2. Turn the regulator knob counter-clockwise to set the outlet pressure to zero.
3. Attach hose and accessories.

Risk of unsafe operation. Firmly grasp air hose in hand when

installing or disconnecting to prevent hose whip.
Risk of unsafe operation. Do not use damaged or worn

accessories.