13 - ENG

N000732

NOTE: The hose or accessory will require a quick connect plug if the air outlet is

equipped with a quick connect socket.

Risk of Bursting. Too much air pressure causes a hazardous

risk of bursting. Check the manufacturer’s maximum pressure rating for air

tools and accessories. The regulator outlet pressure must never exceed the

maximum pressure rating.

Risk of unsafe operation. Compressed air from the unit may

contain wa ter condensation and oil mist. Do not spray un fil tered air at an

item that could be damaged by moisture. Some air tools and accessories may

require filtered air. Read the in struc tions for the air tools and accessories.

How to Start
1. Set the On/Off switch to "On" and allow tank pressure to build. Motor will stop

when tank pressure reaches "cut-out" pressure.

2. Turn regulator knob clockwise to increase pressure and stop when desired

pressure is reached.

If any unusual noise or vibration is noticed, stop the compres-

sor immediately and have it checked by a trained service technician.
The compressor is ready for use.

MAINTENANCE

CUSTOMER RESPONSIBILITIES

Before

each use

Daily

or after

each

use

Check Safety Valve

x

Drain Tank

x

Unit cycles automatically when power is on. When performing

maintenance, you may be exposed to voltage sources, compressed air, or

moving parts. Personal injuries can occur. Before performing any maintenance

or repair, disconnect power source from the compressor and bleed off all air

pressure.
NOTE:
See Operation section for the location of controls.

TO CHECk SAFETY VALVE

Risk of Bursting. If the safety valve does not work properly,

over-pressurization may occur, causing air tank rupture or an explosion.

Risk from Flying Objects. Always wear certified safety

equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
1. Before starting compressor, pull the ring on the safety valve to make sure

that the safety valve operates freely. If the valve is stuck or does not operate

smoothly, it must be replaced with the same type of valve.