beautypg.com

Limiting values, Handling, Thermal characteristics – Philips TDA8767 User Manual

Page 6

background image

1999 Feb 16

6

Philips Semiconductors

Preliminary specification

12-bit high-speed Analog-to-Digital
Converter (ADC)

TDA8767

LIMITING VALUES

In accordance with the Absolute Maximum Rating System (IEC 134).

Note

1. The supply voltages V

CCA

, V

CCD

and V

CCO

may have any value between

0.3 V and +7.0 V provided that the supply

voltage differences

V

CC

are respected.

HANDLING

Inputs and outputs are protected against electrostatic discharges in normal handling. However, to be totally safe, it is
desirable to take normal precautions appropriate to handling integrated circuits.

THERMAL CHARACTERISTICS

SYMBOL

PARAMETER

CONDITIONS

MIN.

MAX.

UNIT

V

CCA

analog supply voltage

note 1

0.3

+7.0

V

V

CCD

digital supply voltage

note 1

0.3

+7.0

V

V

CCO

output supply voltage

note 1

0.3

+7.0

V

V

CC

supply voltage difference

V

CCA

V

CCD

1.0

+1.0

V

V

CCO

V

CCD

1.0

+4.0

V

V

CCA

V

CCO

1.0

+4.0

V

V

I

input voltage

referenced to AGND

0.3

V

CCA

V

V

i(p-p)

input voltage for differential clock
drive (peak-to-peak value)

V

CCD

V

I

O

output current

10

mA

T

stg

storage temperature

55

+150

°

C

T

amb

operating ambient temperature

0

70

°

C

T

j

junction temperature

+150

°

C

SYMBOL

PARAMETER

VALUE (TYP.)

UNIT

R

th j-a

thermal resistance from junction to ambient in free air

75

K/W