5.9. Other

Jumpers

5.9.1. J13 (NOOC)

This jumper will set the OC capabilities in the hub’s descriptors (see Table 5-4).

Table 5-4: Overcurrent Support Selection Using J11 and J12


*—Default settings.

Note: this jumper is for setting the hub’s descriptor only. To inhibit the overcurrent detection,

the OC pins must be tied to V

CC

(5 V)

5.9.2. J14 (SUSPEND)

This jumper is provided for debugging purposes. Logic 1 on the SUSPEND signal indicates that
the hub is in the suspend mode. In the default setting jumper J14 is used (pulled down to GND).

Table 5-5: J14 Mode Setting

6. Schematics

J13

NOOC

Logic State

OFF

No overcurrent support

1 (HIGH)

ON

Overcurrent support*

0 (LOW)

J14

Mode

OFF Debugging

purpose

ON

Normal mode (default)