beautypg.com

Storage – Porter-Cable N039112 User Manual

Page 14

background image

14 - ENG

Safety

Valve Regulator Manifold

Gauges

Quick

Connect

Console Cover

5. Remove the hose by removing the hose clamp.

NOTE: The hose clamp is not

reusable. You must purchase a new hose clamp, see

Replacement Parts in

the Service section or purchase a standard hose clamp at a local hardware

store.

6. Remove pump mounting screws securing pump (one on each side).

Hose

Clamp

Pump Mounting Screw

7. Carefully slide pump from brackets

Regulator

Manifold

Pump

shown

moved

out of the

way

and out of the way.

8. Using an adjustable wrench remove

the regulator manifold.

9. Apply pipe sealant to new regulator

manifold and assemble, tighten with

wrench.

10. Reapply pipe sealant to gauges,

quick connect, and safety valve.

11. Reassemble all components in reverse order of removal. Make sure to orient

gauges to read correctly and use wrenches to tighten all components.

STORAGE

Before you store the air compressor, make sure you do the following:
1. Review the Maintenance section on the preceding pages and perform

scheduled maintenance as necessary.

2. Drain water from air tank. See

To Drain Tank under Maintenance.

Water will condense in the air tank. If not drained, water will

corrode and weaken the air tank causing a risk of air tank rupture.
3. Protect the electrical cord and air hose from damage (such as being stepped

on or run over). Wind them loosely around the compressor handle.

4. Store the air compressor in a clean and dry location.