ELECTRICAL CONNECTIONS

(CONT.)

44

Installation Instructions

4-WIRE POWER CORD INSTALLATION

WARNING:

The neutral wire

of the supply circuit must be connected
to the neutral terminal located in the lower
center of the terminal block. The power leads
must be connected to the lower left and the
lower right terminals of the terminal block.
The 4th grounding lead must be connected
to the frame of the range with the ground
plate and the ground screw.

Remove the 3 lower terminal screws from
the terminal block. Remove the ground screw
and ground plate and retain them.

Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.

Insert the one ground screw into the power cord
ground wire terminal ring, through the ground
plate and into the frame of the range.

Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and into
the lower terminals of the terminal block. Be certain
that the center wire (white/neutral) is connected
to the center lower position of the terminal block.
Tighten screws securely into the terminal block.

Skip to Step 8 and proceed with the installation.

D

E

C

B

A

5

3-WIRE POWER CORD INSTALLATION

WARNING:

The neutral or ground

wire of the power cord must be connected
to the neutral terminal located in the center
of the terminal block. The power leads must
be connected to the lower left and the lower
right terminals of the terminal block.

Remove the 3 lower terminal screws from
the terminal block. Insert the 3 terminal screws
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position of
the terminal block. Tighten screws securely
into the terminal block.

DO NOT remove the ground strap
connection.

Skip to Step 8 and proceed with
the installation.

B

4

A

Terminal block
(appearance
may vary)

Neutral
terminal

B

Be

effo

orre

e

A

Afftte

err

Terminal
block

Terminal
block

Neutral
terminal

Neutral
terminal

Ground strap

Ground plate
(grounding to
range)

Ground
screw

Power cord

Ground plate

Ground strap

or

Ground
strap