Cat. No.: 06-6800-056
Table 3-1: Troubleshooting Steps
Symptom
Corrective Steps
Is it safe to keep
the Midspan
running while a port
indicator is orange?
This is a safe condition. The orange indication is due to:
1. A device, not compliant to IEEE 802.3af, was detected.
2. Terminals 4/5 and 7/8 are shorted together.
3. Forced external power fed into the port.
During these conditions, port power is disconnected.
Technical Specifications
Physical Specifications
Dimensions
44 x 433 x 302 mm
(h x w x l)
(1.75 x 17 x 11.9 inch)
Weight
4 kg (8.8 lb)
Environmental Specifications
Temperature
- Operating
0 to 40 °C (32 to 104 °F)
- Storage
-20 to 70 °C (-4 to 158 °F)
Humidity
10 to 90% (non-condensing)
Electrical Specifications
Parameter
PD-6006
PD-6012
PD-6024
AC Input Voltage
90 to 264 VAC at 47-63 Hz
DC Input Voltage
46 to 57 VDC
Input Current @ 115 VAC
4 A max.
Input at 48 VDC
10 A max.
Total Output Power (1)
92 W max.
200 W max.
200 W max.
Output Power, per Port
15.4 W (not to exceed Total Output Power)
Nominal Output Voltage
44 to 57 VDC
Total Output Power (2)
400 W