SAFETY RULES
The warranty on your WW Electric Burnout Furnace and the WW Computerized Programmer
does not cover damage from overfiring, regardless of the circumstances. It is the operator's
responsibility to make sure that the furnace turns off at the end of the firing. Follow the safety
rules below in addition to the safety rules for your furnace.
UNPLUG THE FURNACE WHEN NOT IN USE.
DO NOT LEAVE THE FURNACE UNATTENDED NEAR END OF FIRING.
WEAR FIRING SAFETY GLASSES WHEN LOOKING INTO PEEPHOLE OF A HOT
FURNACE.
DO NOT TOUCH HOT SIDES OF FURNACE.
INSTALL YOUR FURNACE AT LEAST 12 INCHES FROM ANY WALL, EQUIPMENT OR
COMBUSTIBLE SURFACE.
DO NOT OPEN FURNACE DOOR UNTIL FURNACE HAS COOLED AND ALL SWITCHES
ARE OFF.
FIRE ONLY IN A WELL-VENTILATED, COVERED AND PROTECTED AREA AWAY FROM
FLAMMABLE MATERIALS. KEEP CORDSET AWAY FROM HOT SIDES OF FURNACE.
" DANGEROUS VOLTAGE " ! - DO NOT TOUCH HEATING ELEMENTS WITH ANYTHING.
DISCONNECT FURNACE BEFORE SERVICING.
NOT FOR HOUSEHOLD USE.
KEEP UNSUPERVISED CHILDREN AWAY.
TIME AND TEMPERATURE DISPLAY
During time display, a center display period appears. During temperature display, the period
disappears. The center display period separates hours from minutes (EXAMPLE - 1 hour and 30
minutes displays 01.30). NOTE THIS PECULIARITY: You can enter up to 99 hours and 99 minutes,
displayed as 99.99. In this example, .99 would seem to be tenths and hundredths of hours, yet .99
is 99 minutes.
HOW TO SELECT
°°°°F OR °°°°C
If the controller is in
°°°°C mode, a lighted dot appears in the lower right side of the display. No dot
will appear if the unit is in the
°°°°F mode. To change from °°°°F to °°°°C, turn controller on, press ENTER (
* ) until the display shows [ IdLE ]. Then press (
°°°°F/°°°°C) "0" button repeatedly until [ CHG ]
appears on the display. Press ENTER ( * ) and [
°°°°F ] appears in the display. Press the #1 button to
change to [
°°°°C]. Press Enter to save the change. To change from °°°°C to °°°°F, repeat the above