Installation, Technical specifications – weld-pak 3200hd – Lincoln Electric WELD-PAK 3200HD User Manual
Page 8

A-1
WELD PAK 3200HD
A-1
Fuse or
Output Mode
Input Voltage
Breaker Size
1
Input Amps
Power Cord
Extension Cord
Three Conductor
#14 AWG
(2.1 mm
2
) or Larger
RATED
120V/60Hz
20 Amp
20
15 Amp, 125V,
Up to 25 Ft. (7.6 mm)
Three Prong Plug
Three Conductor
(NEMA Type 5-15P)
#12 AWG
(3.3 mm2) or Larger
Up to 50 Ft. (15.2 mm)
INSTALLATION
TECHNICAL SPECIFICATIONS – WELD-PAK 3200HD
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
12.0 in
9.75 in
16.5 in
48 Ibs
305 mm
248 mm
419 mm
21.8 kg
PHYSICAL DIMENSIONS
Standard Voltage/Frequency
Input Current
120V/60Hz
20 Amps - Rated Output
Duty Cycle
Amps
Volts at Rated Amperes
20% Duty Cycle
90
19
Welding Current Range
Maximum-Open Circuit Voltage
50 - 300 in/min
25-135 Amps
29V
(1.3 - 7.6 m/min)
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.