Linear AM-KP User Manual
Am-kp, Access control keypad, Installation instructions
IN
S
T
R
A
M
/I
I-
K
P
L
in
e
a
r
P
/N
:
2
1
1
5
6
0
D
M
a
te
ri
a
l:
2
0
L
b
.
M
e
a
d
B
o
n
d
S
iz
e
:
8
.5
0
0
"
x
1
1
.0
0
0
"
In
k
:
B
la
c
k
S
c
a
le
:
1
-1
S
id
e
1
o
f
2
AM-KP
Access
Control
Keypad
Installation
Instructions
INTRODUCTION
The AM-KP keypad is designed for use with Linear’s
AM/II access control system. The keypad is housed in a
rugged cast aluminum enclosure. The die-cast keys have
bright, easy-to-read yellow graphics. Each key has a
positive tactile “click” feel when pressed. An internal
sounder signals when a key is pressed.
The keypad can be mounted to a pedestal or directly to
a wall. A keylock secures the keypad to the mounting
backplate.
An incandescent panel lamp lights the keypad for
nighttime use. Red, green and yellow indicators show
power, access and lockout conditions.
The AM-KP is normally powered from the AM/II control,
or can be powered locally from a 12 VDC power supply.
Robust static and lightning protection circuits safeguard
the keypad’s electronics.
A rotary switch selects the keypad’s device address.
Each device connected to the AM/II must be set to a
different device address.
1. AM-KP FEATURES
2. PLAN INSTALLATION
3. MOUNT BACKPLATE
4. ROUTE CABLE
*
5
6
7
8
9
0
#
1
2
3
4
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
D E V I C E
A D D R E S S
S E L E C T O R
( 1 - 6 )
P O W E R / D A T A
T E R M I N A L S
S O U N D E R
K E Y L O C K
*
5
6
7
8
9
0 #
1
2
3
4
T A C T I L E
K E Y P A D
Y E L L O W " L O C K O U T "
I N D I C A T O R
R E D / G R E E N P O W E R / A C C E S S
I N D I C A T O R
N I G H T L I G H T
LOBBY
ACCOUNTING
SERVICE
SALES
COMPUTER
ROOM
V.P.
V.P.
SALES
PURCH.
ENGINEERING
BATH
BATH
STOR.
COPIER
AREA
CHIEF
ENG.
LAB
PRESIDENT
AM/II
CONTROL
COMMERICAL
INSTALLATION
AM-KP
ACCESS
KEYPADS
CARD
READERS
(USING AM-CRI
INTERFACE)
APARTMENT GATE
INSTALLATION
PLAN THE LOCATIONS
FOR CONTROL AND
REMOTE DEVICES
AM-KP
ON
PEDESTAL
AM/II
CONTROL
PLAN CABLE RUNS
BETWEEN CONTROL
AND REMOTE DEVICES
APARTMENTS
PEDESTAL
MOUNT BACKPLATE WITH
SECURITY BOLTS AND LOCKNUTS
USE CONCRETE
WEDGE ANCHORS
OR MOLLY ANCHORS
WALL MOUNTING
CABLE LENGTH FORMULA FOR EACH KEYPAD USED IN SYSTEM
CABLE RUN
CABLE TYPE
FORMULA
300 FEET MAXIMUM
BELDEN 9931 (24 AWG)
WEICO 9405 (20 AWG)
EACH AM-KP KEYPAD EQUALS 9 LOAD UNITS
FEET x LOAD UNITS < 3,000 MAXIMUM
FEET x LOAD UNITS < 10,000 MAXIMUM
HOMERUN WIRE
EACH KEYPAD
(1000 FEET WIRE MAXIMUM
ALLOWED IN SYSTEM)
500 FEET MAXIMUM