RMC-LCNG, RMC-LCLP, RMC-LING, RMC-LILP Specifications

Models

(Manual &

Thermostat)

Gas Type

Input Rating

(Btu/Hr) Variable

Regulator

Pressure

Setting

Inlet Gas Supply

Pressure

Size

of Heater

Weight

Min.

Max

Min.

Max

RMC-LC30NG

Natural

15,000

30,000

4.0” w.c.

5.0” w.c.

11” w.c.

27”x 24”x8

1/2

30 lbs.

RMC-LC20NG

10,000

20,000

19

3/8

”x 22

7/8

”x8

1/2

22 lbs.

RMC-LC10NG

5,000

10,000

15

1/2

”x 20

7/8

”x7

7/8

17 lbs.

RMC-LC30LP

LP

15,000

30,000

10” w.c.

11.0” w.c. 14.0” w.c.

27”x 24”x8

1/2

30 lbs.

RMC-LC20LP

10,000

20,000

19

3/8

”x 22

7/8

”x8

1/2

22 lbs.

RMC-LC10LP

5,000

10,000

15

1/2

”x 20

7/8

”x7

7/8

17 lbs.

RMC-LI30NG

Natural

6,400

30,000

27”x 24”x8

1/2

30 lbs.

RMC-LI18NG

6,400

18,000

19

3/8

”x 22

7/8

”x8

1/2

22 lbs.

RMC-LI10NG

5,500

10,000

15

1/2

”x 20

7/8

”x7

7/8

17 lbs.

RMC-LI06NG

-

6,000

15

1/2

”x 20

7/8

”x7

7/8

17 lbs.

RMC-LI30LP

LP

6,400

30,000

10” w.c.

11.0” w.c. 14.0” w.c.

27”x 24”x8

1/2

30 lbs.

RMC-LI18LP

6,400

18,00

19

3/8

”x 22

7/8

”x8

1/2

22 lbs.

RMC-LI10LP

5,500

10,000

15

1/2

”x 20

7/8

”x7

7/8

17 lbs.

RMC-LI06LP

-

6,000

15

1/2

”x 20

7/8

”x7

7/8

17 lbs.

NOTE:

For altitude above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level.

DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET

LOCAL CODES

Install and use heater with care. Follow all local codes. In the
absence of local codes, use the latest edition of the National
Fuel Gas Code ANSI Z223.2, also known as NFPA54.

Available from:
American National

National Fire Protection

Standards Institute, Inc.

Association, Inc.

1430 Broadway

Batterymarch Park

New York, NY 10018

Quincy, MA 02269

RMC-LC30 / RMC-LC20 / RMC-LC10

RMC-LI30 / RMC-LI18 / RMC-LI10 / RMC-LI06

Certified to ANSI Z21.11.2b-2004 Unvented Heaters

This heater has a pilot with an Oxygen Depletion Sensor Shut-
off system (ODS). The ODS pilot is a required feature for vent-
free heaters. The ODS pilot shuts off the heater if the normal air
oxygen content is reduced below 18%.

This heater has a piezo ignitor. This system requires no match-
es, batteries or other electrical sources to light the heater.

PRODUCT FEATURES

SAFETY DEVICE

PIEZO IGNITION SYSTEM

This manual is related to the following products: