NOTE: The timer switch must be installed in a wall box that has a Load

connection. The matching remote switch

must be installed in a wall box

with a Line Hot connection and a Neutral connection. A Neutral wire to

the matching remote switch needs to be added as shown.
If you are unsure about any part of these instructions, consult an

electrician.
NOTE: Maximum wire length from timer switch to all installed remote

switches cannot exceed 300 ft (90 m).

WIRING VIZIA MATCHING REMOTE SWITCH

(wall box with Line Hot connection):

Connect wires per WIRING DIAGRAM as follows:

• Green or bare copper wire in wall box to Green terminal screw.

• Line Hot (common) wall box wire identified (tagged) when removing

old switch and First Traveler to remote terminal screw marked "BK".

• Second Traveler wall box wire from switch to remote terminal

screw marked "YL/RD"

(note wire color). This traveler from the remote

must go to the Yellow/Red lead on the timer switch.

• Line Neutral wall box wire to remote terminal screw marked "WH".

WIRING TIMER SWITCH (wall box with Load connection):

Connect wires per WIRING DIAGRAM as follows:

• Green or bare copper wire in wall box to Green lead.

• Load wall box wire identified (tagged) when removing old switch to

Red lead.

• First Traveler Line Hot to Black lead.

• Remove Red insulating label from Yellow/Red lead.

• Second Traveler wall box wire

(note color as above) to Yellow/Red

lead. This traveler from the timer switch must go to the terminal screw

on the remote switch marked "YL/RD".

• Line Neutral wall box wire to White lead.

• Proceed to Step 5.

3-Way Wiring with Vizia + Matching

Remote Switch (w/LED) Application:

BK

RD

YL/RD

Additional

Neutral Wire

Matching Remote Switch

3

5

1

2

4

Timer Switch

1

2

Black

White

Red

4

Yellow/Red

Green

3

5

WH

Hot (Bla c k )

Neutral (White)

Timer Switch

Matching Remote Switch (with LED)

YL/RD

RD

YL/RD

WH

BK

BK

Black

White

Line

120VAC, 60Hz

WH

Load

Green

Ground

Green

Ground

• Restore power at circuit breaker or fuse.
• Press any timer button to turn the load on.

If the load does not turn ON, refer to the

TROUBLESHOOTING section.

Timer Switch Mounting:

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

Installation may now be completed by

tightening mounting screws into wall box.

Attach wallplate.

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,

at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to

Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, NY 11747. This warranty excludes and there is disclaimed liability for labor for

removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions.

There are no other or implied

warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,

indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

PK-93796-10-00-2A

© 2009 Leviton Mfg. Co., Inc.

Testing your Timer Switch prior to mounting in

wall box:

• Position all wires to provide room in

outlet wall box for device.

• Ensure that the word “TOP” is facing

up on device strap.

• Partially screw in mounting screws in

wall box mounting holes.

NOTE: Dress wires with a bend as

shown in diagram in order to relieve

stress when mounting device.

Step 5

Step 4c

Step 6

Restore Power:

Restore power at circuit breaker or fuse.

Installation is complete.

Step 7

1. To turn the load ON press one of the timer buttons. The green LED

adjacent to that button will illuminate and the timer will begin to

countdown for the selected timer period.

2. To select a different countdown time press the button corresponding to

the desired time. The LED adjacent to that button will illuminate and the

timer will begin countdown from the new selection.

3. To turn the load OFF press the OFF button or wait until the selected

amount of time has passed. The LED adjacent to each button will

extinguish as time passes to the next preset level.

OPERATION

For additional information, contact Leviton’s

Techline at 1-800-824-3005 or visit Leviton’s

website at www.leviton.com

Covered by one or more US & Foreign

Patents and patents pending

© 2009 Leviton Manufacturing Co., Inc.

All Rights Including Trade Dress Rights Reserved

• Degree of protection provided: IP20
• Type of Action: 1Q

FCC COMPLIANCE STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject

to following two conditions: (1) this device may not cause harmful

interference, and (2) this device must accept any interference received,

including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for

a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These

limits are designed to provide reasonable protection against harmful

interference in a residential installation. This equipment generates, uses,

and can radiate radio frequency energy and, if not installed and used in

accordance with the instructions, may cause harmful interference to radio

communications. However, there is no guarantee that interference will

not occur in a particular installation. If this equipment does cause harmful

interference to radio or television reception, which can be determined

by turning the equipment OFF and ON, the user is encouraged to try to

correct the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.

• Increase the separation between the equipment and the receiver.

• Connect the equipment into an outlet on a circuit different from that to

which the receiver is connected.

• Consult the dealer or an experienced radio/tv technician for help.

FCC CAUTION

Any changes or modifications not expressly approved by Leviton

Manufacturing Co., Inc., could void the user's authority to operate the

equipment.

TROUBLESHOOTING

• Intermittent Operation
- Load has a bad connection.

- Wires not secured firmly to leads of timer switch

and/or remote switch.

• Load does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.

- Load is burned out.

- Neutral connection is not wired.
• Remote does not operate load
- Ensure that total wire length does not exceed 300 ft (90 m).

- Ensure that a neutral wire is used with matching remote switches.

Timer Select Mode - You can change the time outs on your timer

without buying a new device!

ADVANCED PROGRAMMING FEATURE

• Four (4) Timer buttons and an OFF button.

• Each timer button has an adjacent green LED to indicate the current

countdown time.

• The green bottom LED is ON when the load is OFF and is OFF when

the load is ON.

• Your timer switch can be easily programmed to function as 1 of 4 timers.

• LTB02 is not programmable as a 12 hour timer but can be programmed to

function as any of the other timers.

Timer Override
To override the Timer countdown press and hold the top button for several

seconds. The locator LED will turn amber to indicate the EXTENDED ON

state. In this state the timer will automatically turn OFF after 24 hours. To exit

the EXTENDED ON state press any of the timer buttons or the OFF switch.

Your timer can be programmed to function as any of the timers in the

table below:

NOTE: If you change the ON times of your timer the printed face will no

longer match the ON times. A timer change kit should be purchased to

alleviate this situation.

To select different on times please follow the subsequent steps:
1.
Press and hold the 1st and 3rd timer buttons to enter Select Timer Mode.

2. The current active Timer LED will flash green to indicate the device is in

Select Timer Mode.

3. Press the button (from the table above) corresponding with the time outs

you desire.

4. The new Timer button will briefly flash to demonstrate the timer mode

chosen.

5. Pressing the OFF button will save programming and exit programming

mode. The timer will also exit programming mode automatically if no

buttons are pressed for 3 minutes.

Multi-Location Control
The Timer can be turned ON or OFF from any of the Vizia +

®

Remote

Switch locations. The default ON time when a remote is pressed to turn

the load ON will be the last countdown time chosen. The timer can be

controlled from up to 10 locations using Vizia + Coordinating Remote

Switches or up to 5 locations using Vizia + Matching Remote Switches.

NOTE: Sharing a neutral wire may cause improper operation. Connect all

timers to the same phase or run a seperate neutral to each phase.

FEATURES OF YOUR COUNTDOWN TIMER SWITCH

Button 1 - Longest ON time

Button 2

LED indicator

lights

Locator LED

Button 3

Button 4 - Shortest ON time

OFF switch

Timer buttons

+

Timer Switch Number

Buttons

Time outs

LTB02

1 (top timer button)

15m, 30m, 1hr, 2hr

LTB12

1 (top timer button)

2, 4, 8, 12 hours

LTB60

2

10, 20, 30, 60 minutes

LTB30

3

5, 10, 15, 30 minutes

LTB15

4 (bottom timer button)

2, 5,10,15 minutes

N/A