Leviton Plug-In Serial Interface Module RZCP User Manual
Page 2
lIMItED 5 YEaR WaRRaNtY aND EXCluSIoNS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the
purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to leviton
Manufacturing Co., Inc., att: Quality assurance Department, 59-25 little Neck Parkway, little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation.
This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any
labels or instructions. there are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such
implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or
loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
oPERatIoN
NotE: For complete details on operating the
Primary Programmer/Remote, refer to the
instruction guide for that particular device.
The RZCØP is intended for use by developers
who want to develop products that can transmit
signals to and receive signals from ViziaRF
TM
products on a Z-Wave
TM
network. A relatively
high level of programming knowledge is required
to develop products that use these interfaces.
The interface uses a simple ACSII protocol to
communicate to the controlling equipment. If you
are an end user who has purchased this product
to work with another product that was designed
for this purpose, please refer to that product’s
owner’s manual for operating instructions.
If you are a developer who has purchased this
interface to develop a ViziaRF
TM
compatible
product, you will need the RZCØP Tech Note,
which contains the information needed to allow
proper interface communication. Please visit our
website listed below to download the RZCØP
Tech note.
• Plug-In Serial Interface Module is
functioning improperly
- Confirm that the device is being supplied
from a 120V, 60Hz AC source ONLY.
- Confirm that the unit is programmed
properly. Repeat “INSTALLING YOUR
INTERFACE MODULE” section to verify
that it has been included into the Z-Wave
TM
network.
• Programmer/Remote does not operate
lights
- Check association.
- Ensure that Plug-In Serial Interface Module
was properly updated.
tRouBlESHootING
DI-000-RZC0P-00C
For additional information, contact leviton’s
techline at 1-800-824-3005 or visit leviton’s
website at www.ViziaRF.com
Protected under U.S. Patent Number 6,388,399
and patents pending and licensed under U.S.
Patents Numbers 5,905,442, and 5,982,103
NotE: It is very important to accurately
Exclude devices from the network when
moving or removing a device from a Z-Wave
TM
network. This ensures that all information has
been removed from your Primary Programmer/
Remote’s information table and is not counted
on to be a part of the mesh network.
a) If using a Leviton Z-Wave
TM
Programmer/
Remote, Cat. No. RZCPG, press the Menu
button and scroll down to System Setup.
Press the center button to select System
Setup Menu. Press the center button to
select Network. Scroll down to Node> and press the center button. B) If using RZCPG Programmer/Remote you will be prompted to prepare device for exclusion. To do this, you must put the Plug-In Serial Interface Module into programming mode. C) To access Program mode, press and hold programming button until the LED turns Amber. You are now in Programming mode. NotE: If the LED on the Plug-In Serial Interface Module turns solid Red while excluding, there has been a communication error. D) While standing close to the Plug-In Serial Interface Module (approximately 2-5 ft.), press the center button to from the network. Excluding Plug-In Serial Interface Module from Network: Step 4 This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ tv technician for help. FCC CoMPlIaNCE StatEMENt Factory Default: If your module is not responding, or you are unable to control it after you have tried to Include/ Exclude it multiple times, it may be necessary to reset the module to its original factory settings. To accomplish this, proceed as follows: the LED flashes Amber and then turns solid Red. Release the button and wait until the LED blinks Green. NotE: This can take up to a minute. The module is now reset. Once the module is reset, it will be necessary to Re- Include it to a network before it can be used. CautIoN: SETTING A DEVICE TO A FACTORY DEFAULT DOES NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE EXCLUSION PROCEDURE MUST STILL BE FOLLOWED TO REMOVE THE DEVICE FROM THE PRIMARY REMOTE’S INFORMATION TABLE. FAILURE TO DO SO MAY RESULT IN SYSTEM THAT IS SLOW TO RESPOND, OR MAY FAIL TO RESPOND TO SOME DEVICES. Wall Receptacle RS232 Cable Plug-In Serial NOTE: Programmer/Remote must be in RZCPG Programmer/ Including Plug-In Serial Interface Module into Z-Wave tM Network: Step 3 cont’d Step 4 cont’d www.ViziaRF.com CoMMuNICatIoN SEttINGS NotE: The following general information applies to the RS232 Interface. interface, use the following data conventions: PC, run the Microsoft Windows ® Hyper Terminal program or an equivalent program. Then select Local Echo, Line Feed and Carriage Return inbound and outbound. This allows you to see the characters that you are typing as well as keep the responses from overwriting typed characters.
• Reorient or relocate the receiving Antenna.
• Increase the separation between the
• Press and hold the programming button until
Interface Module
close proximity to Plug-In Serial Interface
Module when including into network
Remote
To configure your device to communicate with the
9600 BauD
8 Data
1 StoP
No PaRItY
If you wish to send these commands from a