Troubleshooting, Connection of the la36 with the cs16, Action – Linak TECHLINE LA36 User Manual
Page 15: Possible cause, Symptom

15
Troubleshooting
Action
• Connect the actuator to the
 power 
supply
• Change cable
• Send actuator for repair
 
• Align or reduce load
• Send actuator for repair
• Send actuator for repair
• Send actuator for repair
• Change cable
• Send actuator for repair
• Increase power supply
• Thicker cable
• Reduce load
Possible cause
• The actuator is not connected
to the power supply
• Cable damaged
• Misalignment or overload in
application
• Gearwheel or spindle 
 damaged
• Clutch is worn 
• Motor is damaged
• Cable damaged
• Potentiometer damaged
 
• Insufficient power supply
• Voltage drop in cable
• Load is higher than specified
Symptom
No motor sound or 
movement of piston rod
Excessive electricity 
consumption
Motor runs but spindle 
does not move
Actuator cannot lift full 
load
No signal from 
potentiometer or hall 
effect sensor
Motor runs too slowly or 
does not give full force
Actuator cannot hold the 
chosen load
1 2 3 4 5 6 7 8 9 10 11 12
CS16-4-24
MAX MIN
P
HB40 serie
-
+
R = RED . O = ORANGE . GR = GREEN
R GR O
Connection of the LA36 with the CS16
