1101hcb, Lytecaster, Performance recessed cfl downlighting – Lightolier 1101HCB User Manual
Page 2

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • A0409
Lytecaster
®
Performance Recessed CFL Downlighting
1101HCB
Page 2 of 2
6 ¾" Aperture Horizontal Cross Blade, CFL, Performance Series, Reflector Trim
Job Information
Type:
32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, WHITE CROSS BLADE
42W TRIPLE TUBE LAMP, LUMEN RATING = 3200 LMS, ELECTRONIC BALLAST, WHITE CROSS BLADE
60°
30°
1
2
225
450
695
900
2
1
167
333
500
666
60˚
30˚
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30 390.66
17.8
47.9
0-40 550.53
25
67.5
0-60 726.61
33
89.1
0-90 815.38
37.1
100
90-120 0
0
0
90-130 0
0
0
90-150
0
0
90-180 815.38
37.1
100
** Efficiency = 37.1% **
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room
Cavity
Ratio
0 44 44 44 44 43 43 41 41 39 39 37
1 41 40 38 37 39 37 37 36 36 34 33
2 38 36 34 32 35 32 34 31 33 30 29
3 36 32 30 28 35 32 28 31 27 30 26
4 33 30 27 25 29 25 28 24 27 26 23
5 31 27 24 22 27 22 26 22 25 22 21
6 29 25 22 20 25 20 24 20 23 20 19
7 27 23 20 18 23 18 22 18 22 18 17
8 26 21 19 17 21 17 21 17 20 17 16
36 24 20 17 16 20 16 19 16 19 15 15
10 23 19 16 15 19 14 18 14 18 14 14
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 35
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
59.95
10-20
147.91
20-30
183.79
30-40
159.87
40-50
103.2
50-60
72.98
60-70
50.18
70-80
28.8
80-90
9.7
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle
0˚ CP
90˚ CP
0
666
666
5
635
637
10
572
597
15
494
582
20
432
528
25
383
468
30
324
401
35
263
287
40
193
177
45
142
116
50
106
97
55
80
80
60
64
64
65
51
51
70
39
39
75
27
28
80
17
18
85
8
9
90
5
5
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30
498.04
15.6
47.7
0-40
701.05
21.9
67.2
0-60
929.8
29.1
89.1
0-90 1043.73
32.6
100
90-120
0
0
0
90-130
0
0
0
90-150
0
0
0
90-180 1043.73
32.6
100
** Efficiency = 32.6% **
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room
Cavity
Ratio
0 39 39 39 39 38 38 36 36 35 35 33
1 36 35 34 33 34 32 33 31 32 30 29
2 34 31 30 28 31 28 30 27 29 27 25
3 31 29 26 25 28 24 27 24 26 24 23
4 29 26 24 22 26 22 25 21 24 21 20
5 27 24 21 20 23 19 21 19 20 19 18
6 26 22 19 18 22 18 21 17 21 17 17
7 24 20 18 16 20 16 20 16 19 16 15
8 23 19 16 15 19 15 18 15 18 15 14
36 21 18 15 14
17 14
17 14
17 14
13
10 20 16 14 13 16 13 16 13 16 13
12
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 47
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
73.64
10-20
188.16
20-30
236.24
30-40
203
40-50
134.48
50-60
94.28
60-70
64.6
70-80
36.97
80-90
12.35
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle
0˚ CP
90˚ CP
0
816
816
5
778
801
10
701
774
15
604
751
20
526
688
25
466
599
30
394
503
35
325
369
40
249
232
45
185
154
50
136
124
55
104
102
60
82
82
65
65
65
70
50
49
75
35
35
80
22
22
85
11
11
90
2
4
SC = 0.8 x 0.98
1 – 0°
2 – 90°
CERTIFIED TEST REPORT NO. 3353FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
SC = 0.8 x 1.0
1 – 0°
2 – 90°
CERTIFIED TEST REPORT NO. 3356FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**