INITIAL STEPS FOR INSTALLING YOUR DRYER

The following instructions are applicable to
installations of the dryer in a manufactured or
mobile home. Any installation in a manufactured or
mobile home must comply with the Manufactured
Home Construction and Safety Standards Title 24
CFR, Part 32-80 or Standard CAN/CSA0Z240 MH
and local codes and ordinances. If you are
uncertain whether your proposed installation will
comply with these standards, please contact a
service and installation professional for assistance.

The following instructions apply to any installation
of the dryer in a manufactured or mobile home:

1) The gas dryer must be permanently attached to

the floor.

2) The electrical connection for an electric dryer

must be a 4-wire connection. More detailed
information concerning the electrical connection
is provided at the manual section entitled
Electrical Requirements for Electric Dryer

3) To reduce the risk of combustion and fire, the

dryer must be vented to the outside.

4) Electric dryers may be vented to the outside

using the back, left, right, or bottom panel.

5) Gas dryers may be vented to the outside using the

back, left, or bottom panel. Gas dryer may not be
vented to the outside using the right side panel
because of the burner housing.

6) The dryer exhaust duct must be affixed securely

to the manufactured or mobile home structure,
and the exhaust duct must be made of a material
that will resist fire and combustion, and it is
recommended that you use a rigid or flexible
metal pipe.

7) DO NOT connect the exhaust duct with any other

duct, vent, chimney, or other exhaust duct.

8) Make sure the dryer has adequate access to

outside fresh air to ensure proper operation. The
opening for outside fresh air must be at least 25
in

2

(163 cm

2

).

9) It is important that the clearance of the duct from

any combustible construction be at least 2 inches
(5 cm), and, when venting the dryer to the
outdoors, the dryer can be installed with a
clearances of 1 inch at the sides and back of the
dryer.

10) Please be aware that venting materials are not

supplied with the dryer. You should obtain the
venting materials necessary for proper
installation.

WARNING!

DO NOT connect exhaust ducts with
metal screws or fasteners that extend
into the duct.

!

WARNING!

DO NOT vent the exhaust duct under the
manufactured or mobile home.

!