A-13

INSTALLATION

LF-72

A-13

WELD WIRE ROUTING

The electrode supply may be either from reels, Readi-

Reels, spools, or bulk packaged drums or reels.

Observe the following precautions:

a) The electrode must be routed to the wire drive

unit so that the bends in the wire are at a mini-

mum, and also that the force required to pull the

wire from the reel into the wire drive unit is kept at

a minimum.

b) The electrode is “hot” when the gun trigger is

pressed and must be insulated from the boom

and structure.

c) If more than one wire feed unit shares the same

boom and are not sharing the some power source

output stud, their wire and reels must be insulated

from each other as well as insulated from their

mounting structure.

FIGURE A.9