Installation – Lincoln Electric VANTAGE IM10044 User Manual
Page 11

VANTAGE® 575 CUMMINS
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS - VANTAGE® 575 CUMMINS (K2170-2)
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
cu. in. (ltrs.)
System
4 cylinder
High Idle 1590
199(3.3)
12VDC Battery &
Fuel: 25 gal.
Cummins
48 HP (36kw)
starter
(94.6 L)
B3.3
1500 RPM
Full Load 1500 Bore x Stroke inch (mm)
Oil: 2 gal. (7.5L)
Diesel Engine
Low Idle 1300
3.74 X 4.53
Radiator Coolant:
(95 x 115mm)
2.6gal. (9.8L)
INPUT - DIESEL ENGINE
RATED OUTPUT @ 104°F(40°C) - WELDER
Duty Cycle
Welding Output
Volts at Rated Amps
100%
450 Amps (DC multi-purpose)
38 Volts
60%
500 Amps (DC multi-purpose)
40 volts
PHYSICAL DIMENSIONS
Height
(2)
Width
Depth
Weight
42.0 in
32.7 in.
63.1 in.
1625 lbs.
(1066.8 mm)
(830.1mm)
(1603mm)
(737kg)
(Approx)
1.
Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
2.
Top of Enclosure, add 7.0” (177.8mm) for exhaust pipe.
OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR
Welding Range
30 - 575 Amps CC/CV
20 - 250 Amps TIG
Open Circuit Voltage
60 Max OCV @ 1590 RPM
Auxiliary Power
(1)
(50 Hz)
Outlets x Phase
Voltage
Power
Amps
1 x 3ph
415 Volts
20 Kva
32 Amps
2 x 1ph
240 Volts
7.2 Kva
15 Amps