Lowrance electronic Lowrance LMS-522c iGPS User Manual
Page 234
224
ration menu. A list of network devices will be at the top of the page.
3. Select the desired EP-15 Fluid Level and press
ENT
.
4. Press
↓ to select
C
ALIBRATE
and press
ENT
. The Device Calibration
menu will appear.
5. Highlight
N
UM
P
TS
, press
ENT
and select
5
. Press
ENT
.
6.
Make sure your tank is empty, then
highlight
F
LUID
L
EVEL
and press
ENT
.
Select
E
MPTY LEVEL
and press
ENT.
7.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
Empty Level Calibration Completed. Press
ENT
.
8.
Add 1 quarter tank of fuel, highlight
F
LUID
L
EVEL
and press
ENT
.
Select
1
Q
TR
L
EVEL
and press ENT.
9. Select C
ALIBRATE
and press ENT
. The following message will appear: 1
Qtr Level Calibration Completed. Press
ENT
.
10. Add another quarter tank of fuel, which should raise the fuel level
to half a tank. Highlight
F
LUID
L
EVEL
and press
ENT
.
Select
H
ALF LEVEL
and
press
ENT.
11.
Highlight
C
ALIBRATE
and press
ENT
. The following message will ap-
pear: Half Level Calibration Completed. Press
ENT
.
12. Add another quarter tank of fuel, which should raise the fuel level
to 3 quarters of a tank. Highlight
F
LUID
L
EVEL
and press
ENT
.
Select
3
Q
TR
L
EVEL
and press
ENT.
13.
Select
C
ALIBRATE
and press
ENT
. The following message will appear: 3
Qtr Level Calibration Completed. Press
ENT
.
14. Top off the tank, highlight
F
LUID
L
EVEL
and press
ENT
.
Select
F
ULL
L
EVEL
and press
ENT.
15.
Select
C
ALIBRATE
and press
ENT
. The following message will appear:
Full Level Calibration Completed. Press
ENT
, then press
EXIT
repeat-
edly to get back to the main display.
Fuel Flow Calibration in a Suzuki Engine Interface
The default calibration for the Suzuki Engine Interface is adequate in
most cases, but if Fuel Used readings are off by more than 3 percent,
calibration is recommended.
To check engine interface accuracy:
Select Fuel Used to be shown as Overlay Data on your unit's main dis-
play. Refer to the Overlay Data segment of this manual for instructions
on how to select Fuel Used data as Overlay Data.
1. After selecting Fuel Used as overlay data, fill up your tank and press
MENU
|
MENU
.
2. Select
NMEA
2000
and press
ENT
.