A-3

INSTALLATION

A-3

INVERTEC® V350-PRO (CE)

LN-15 Connection Instructions

• Turn the Invertec

®

power switch "off".

• Connect the electrode cable to the output terminal of

polarity required by electrode. (See Figures below)

• Set the meter polarity switch on the front of the Invertec

®

to coincide with wire feeder polarity used.

LN-25 Connection Instructions

• Turn the Invertec

®

power switch "off".

• Connect the electrode cable to the output terminal of

polarity required by electrode. Connect the work lead to
the other terminal.

• LN-25 with Remote Control options can be used with the

"CE" version of the V350. The 6-Pin (K444-1) and 14-pin
(K444-2) remotes can be connected directly to the 6-pin
& 14-pin MS-style connector. The 42 Volt Remote
Voltage and Output Control (K624-1) Kit can be connect-
ed to the V350’s 14-pin MS-style connector using
Remote Control Cable assembly K627- [ ]. LN-25s with a
K431-1 remote kit can be connected to the V350’s 14-pin
MS-style connector using a K432 cable and K876
adapter. (See connection diagram S19899). Or the K432
cable could be modified with a K867 Universal Adapter
Plug (See connection diagram S19405) to connect it to
the V350’s 14-pin MS-style connector.

LN-742 Connection Instructions

• Turn the Invertec

®

power switch "off"

• Either a K591 or a K593 Input cable assembly is

required to connect the LN-742 to the Invertec

®

.

• Connect the control cable from the LN-742 to the

14-pin MS-style connector.

• Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect the
work lead to the other terminal.

• Set the meter polarity switch on the front of the

Invertec

®

to coincide with wire feeder polarity used.

The wire feeder will now display the welding volt-
age.

• If a remote control such as K857 is to be used with

the LN-742, the remote can be connected directly
to the 6-pin MS-style connector on the front of the
Invertec

®

or use a K864 adapter to connect the LN-

742 and the remote to the 14-pin MS-style connector.

Cobramatic Connection Instructions

• Turn the Invertec

®

power switch "off"

• Connect the control cable from the Cobramatic to

the 14-pin MS-style connector.

• Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect the
work lead to the other terminal.

• Set the meter polarity switch on the front of the

Invertec

®

to coincide with wire feeder polarity

used.

• If a remote control such as K857 is to be used

with the Cobramatic, the remote can be connected
directly to the 6-pin MS-style connector on the front
of the Invertec

®

or use a K864 adapter to connect

the cobramatic and the remote to the 14-pin MS-
style connector.

CONNECTION OF WIRE FEEDERS TO V350-PRO (CE)

Wire feeders other than these listed may be used pro-
vided that the auxiliary power supply capacity of the
Invertec

®

is not exceeded. K867 Universal Adapter

Plug may be required. See connection diagram
S24985 on page F-4.

REMOTE CONTROL OF INVERTEC

®

Remote Control K857, Hand Amptrol K963 and Foot
Amptrol K870.

UNDERCARRIAGE MOUNTINGS

14.79

12.44

3.44

21.60

27.82

5.50

10.00

MOUNTING HOLE LOCATIONS

M19527

13.10

1/4-20 NUT (4 PLACES)

NOTE: MOUNTING SCREWS CA

4/01

N NOT PROTRUDE MORE THAN

0.5 INCHES INSIDE THE MACHINE.

11.84

3.50

Work
Clamp

Electrode Cable

Electrode Cable

Electrode Cable

Work
Clamp

Work
Clamp

wire feeder
K1870-1

wire feeder
K1870-1

RANGER 8
SAE 400 WITH CV ADAPTER

ENGINE DRIVEN WELDERS
WITH WIRE FEED MODULE
(LOCAL MODE AND CV ADAPTER)

CV250
CV300
CV400

CC POWER SOURCE

Output Terminals
Always Hot.

Output Terminals
Always Hot.

Output Terminals
Always Hot.

Order K484 Jumper
Plug Kit.

Electrode Cable

Work
Clamp

semiautomatic

semiautomatic

semiautomatic

semiautomatic
wire feeder
K1870-1

wire feeder
K1870-1

wire feeder
K1870-1

CV655, DC400, DC600,
DC655, V350-PRO,

RANGER 9, RANGER 300 DLX
COMMANDER 300
COMMANDER 500
RANGER 2V35050
RANGER 305G

Output Terminals

Output Terminals
Always Hot.

Always Hot.

Power source contactor

Power source contactor
switch must be in the

switch must be in the
"ON" position or use a

"ON" position or use a
K848 Junper Plug Kit.

K848 Junper Plug Kit.

ACROSS THE ARC MODEL

V350-PRO

TWIST-MATE

CONTROL CABLE MODEL

Electrode Cable