Installation – Lincoln Electric Invertec V205-T User Manual
Page 8

TIME-DELAY CIRCUIT BREAKER
OR FUSE SIZE (AMPS)
30A
A-2
A-2
V205-T AC/DC
INSTALLATION
Input Amps
34A
28A
20A
34A
25A
20A
30A
23A
19A
30A
18A
15A
Type of Output
AC/DC
Output Amps Volts at Rated Amperes
(Stick) 110
24.4V
90
23.6V
70
22.8V
(TIG) 150
16V
120
14.8V
100
14V
(Stick) 180
27.2V
150
26V
130
25.2V
(TIG) 200
18V
170
16V
140
15.6V
Maximum Open
Circuit Voltage
54 Volts Max.
Input Voltages / 50 /60 Hz.
115
230
Duty Cycle
(115V) 35%
60%
100%
(115V) 40%
60%
100%
(230V) 35%
60%
100%
(230V) 40%
60%
100%
Output Current
Range
6-200 Amps
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Height
Width
Depth
Weight
15 in.
8.5 in.
19 in.
Approx. 38 lbs.
381 mm
216 mm
483 mm
17 kgs.
PHYSICAL DIMENSIONS
TECHNICAL SPECIFICATIONS - V205-T AC/DC TIG K1855-1 (Code Number 10860)
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-20°C to +40°C
STORAGE TEMPERATURE RANGE
-50°C to +85°C
INPUT
VOLTAGE /
FREQUENCY
(HZ)
115/50/60
230/50/60
TYPE S, SO ST, STO, OR EXTRA
HARD USAGE INPUT CORD AWG
#12
Max. Input Current
34A at Rated Output
30A at Rated Output
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT