Lightolier ALETTA AL2T8 User Manual
Aletta al2t8, Lighting systems

631AirportRoad,FallRiver,MA02720•(508)679-8131•Fax(508)674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com©2010PhilipsGroup•
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lighting Systems
ALETTA AL2T8
Page 1 of 2
LouverShield,2T8LampsperFixture,GridMounted
D1007
Features
1. Housing: 23gaugepre-paintedsteel.20gaugeavailable,consultfactory.
2. Lamp: TwoT8.(byothers)
3. Faux Housing: ExtrudedFrostyacrylic.
4. Louver:HighpuritySemi-Specular,2-3/4"(6.99cm)openingx1-3/8"(3.49cm)
deepon2"(5.08cm)ctrswithmicro-prismaticsideoverlays.Elongatedlens
openingsare22"(55.88cm)windows.
5. Performance Kick Reflector:.020"(0.05cm)95%-98%reflective,UV
resistant polypropylene.
6. Trim:Extrudedaluminumtrim,paintedwhite,interfaceswithceilinggridor
plasterframebyothers.
Electrical
Ballastsareelectronicandhighpowerfactor.Dimmingballastsareavailableon
manylamptypes,pleaseconsultfactoryregardingspecificapplications.1325
maxlumenbatterypackisstandard.Seeapplicationtableonpage2foroutput
with specific lamp types. Continuous luminaires utilize 12 gauge through wires.
Factoryinstalledballastdisconnectallowstheballasttobedisconnectedfromand
reconnected to incoming power under load without turning the entire circuit off.
Mounting
Housingissuspendedbyhangerwiresandlaidintostandardorslot-Tgridceiling.
Mountingaccessoryavailablefordrywallinstallations(seepage2).
Labels
UL,cULandI.B.E.W.
Ordering Instructions
Individual Fixtures:
1. OrderquantityofIndividualUnitsrequired.
Continuous Runs:
1. OrderoneStarterandoneEnderfixtureperrun.
2. OrderappropriatequantityofJoinerfixtures.
Continuousrunsonly-PriortoinstallingAlettainagridceiling,theinstalling
contractormustensurethatthefixturewillsetintotwomainrunners,spaced2'
(60.96cm)oncenter.Nogridcrossmembersarerequiredexceptatthebeginning
and end of the run.
7.00”
(17.78cm)
23.00”
(58.42cm)
2.00”
(5.08cm)
2.75”
(6.99cm)
1
2
5
3
4
6
24.00” (60.96cm)
5.28”
(13.41cm)
7.00”
(17.78cm)
Louver w/ Elongated
Lens Detail
Ordering Information
Family
Shielding
Length
Lamps
Lamp Type
Ballast Factor
Voltage
Housing
Option
A
2
T8
Aletta
LE=Louverw/
Elongated Lens
2=2'(60.96cm)
4=4'(121.92cm)
2 = 2 Lamps T8 =T8
Standard
Output
71 = .71
78 =.78
88 =.88
10 = *1.0 Dimming
and Static
12 = *1.2 Step Dimming
1 = 120v
2 = 277v
3 =347v
U =IndividualUnit
S = Starter
J = Joiner
E = Ender
D = Dimming
E =EMPack
2 = 2 Circuit
4 =4ThroughWire
5 =5ThroughWire
* For dimming, use "D" option. If "D" is not selected, ballast will be static.