background image

2-4. Cooling

TROUBLE

D

IAGNOSIS

-5
7-

Problems

Causes

Checks

Measures

Remarks

High

Refrigerant leak.

Check sequence

Weld the leaking part, recharge the

Drier must be replaced.

temperature

1. Check the welded parts of the

refrigerant.

in the freezer

drier inlet and outlet and drier

compartment.

auxiliary in the compressor

compartment (high pressure side).

2. Check the end of compressor

sealing pipe (low pressure side).

3. Check silver soldered parts.

(Cu + Fe / Fe + Fe).

4. Check bending area of wire

condenser pipe in compressor

compartment (cracks can

happen during bending).

5. Check other parts (compressor

compartment and evaporators in

freezer compartment).

Shortage of refrigerant.

Check frost formation on the surface - Find out the leaking area, repair,

Drier must be replaced.

of evaporator in the freezer

evacuate, and recharge the

compartment.

refrigerant.

- If the frost forms evenly on the

- No leaking, remove the remaining

surface, it is OK.

refrigerant, and recharge new

- If it does not, it is not good.

refrigerant.