Installation – Lincoln Electric MULTI-SOURCE IM692 User Manual
Page 8
A-1
INSTALLATION
MULTI-SOURCE
A-1
TECHNICAL SPECIFICATIONS - Multi-Source K1752-1
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
HEIGHT
30.8 in
781 mm
WIDTH
22.2in
565 mm
DEPTH
41 in
1040 mm
NET WEIGHT
992 lbs.
450.5 kg.
OPERATING TEMPERATURE RANGE
-40 to +122ºF
-40 to +50ºC
STORAGE TEMPERATURE RANGE
-40 to +185ºF
-40 to +85ºC
Volts at Rated Amperes
75
Volts at Rated Amperes
75.8
Amps
533
Amps
475
Duty Cycle
100% Duty Cycle
@ 50°C (122°F)
0-650 A
INPUT - THREE PHASE ONLY
CURRENT RANGE
OCV
RECOMMENDED INPUT WIRE AND FUSE SIZES
Standard Voltage/Frequency
380/415/50
400/60
440/50
460/60
550/50
575/60
100% Duty Cycle
99A
98A
79A
83A
66A
69A
Input Current at Rated Output
RATED OUTPUT
INPUT
VOLTAGE
380-415
460
575
FUSE
(SUPER
LAG)
OR
BREAKER
SIZE
(AMPS)
150 Amp
125 Amp
100 Amp
TYPE
75°C
GROUND
WIRE IN
CONDUIT
AWG(IEC-
MM
2
) SIZES
6 (16)
6 (16)
8 (10)
TYPE 75°C
COPPER
WIRE IN
CONDUIT
AWG(IEC-MM
2
)
SIZES 50°C
(122°F) Ambient
1/0 (70)
2 (35)
3 (35)
TYPE 75°C
COPPER
WIRE IN
CONDUIT
AWG(IEC-MM
2
)
SIZES
40°C
(104°F) Ambient
2 (35)
3 (35)
4 (25)
TYPE 90°C
COPPER
WIRE IN
CONDUIT
AWG(IEC-MM
2
)
SIZES
50°C
(122°F) Ambient
2 (35)
3 (35)
4 (25)
TYPE 90°C
COPPER
WIRE IN
CONDUIT
AWG(IEC-MM
2
)
SIZES 40°C
(104°F) Ambient
3 (35)
4 (25)
4 (25)
INPUT
AMPERE
RATING
99
83
69
HERTZ
50
60
60
Maximum Open Circuit Voltage
80V
60 Hz-40 kW
50 Hz-36 kW