beautypg.com

Power, battery, & ground wiring, Optional remote antenna, Power wiring – Linear RE-2 User Manual

Page 11: Connect coax to antenna connector

background image

9

POWER, BATTERY, & GROUND WIRING

Power Wiring

NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS

COMPLETE.

1. Route two wires between the RE-2 and the power transformer.

• For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt

insulated wire.

• For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt

insulated wire.

2. Connect the wires to the transformer. Connect the other end of the

wires to the two RE-2 TRANSFORMER terminals.

Backup Battery

Use of battery backup is optional. It will allow the RE-2 to operate for
short periods of time without AC power. Two 12-volt backup batteries
in series are recommended to obtain the proper working voltage
for the RE-2. A single 12-volt battery can be used, although the call
waiting beeps and the ring voltage will be lower than normal when fi ve
telephones are connected. The door or gate access device must use
some type of battery backup for the entire system to be functional.
Backup batteries will not fi t into the RE-2 housing. Protect the backup
batteries inside a rain-tight NEMA enclosure suitable for the installation.

NOTE: Backup batteries are not required to maintain the RE-2 clock/

calendar and programming memory during power outages.

1. Route two wires between the RE-2 and the backup batteries.
2. Connect two 1.2 Amp/hour (minimum), 12-volt, gel cell batteries in

series (Battery #1 negative to Battery #2 positive).

3. Connect the Battery #1 positive to the RE-2 BATTERY POSITIVE terminal.
4. Connect the Battery #2 negative to the RE-2 BATTERY NEGATIVE

terminal.

NOTE: The RE-2 does not supply battery charging current. An

external battery charger will be required to maintain the batteries.

Earth Ground

For the best ground, use size 12 gauge solid wire or larger to connect
to an 8-foot copper ground rod. Locate the ground rod next to the
Power and Telephone company rods and bond the rods together
with a new clamp. Do not disturb the clamps installed by the Power
or Telephone Company. Alternately, connect to a cold water pipe for
the earth ground.

1. Connect the wire from the earth ground to the rear case ground stud.
2. Connect the Telephone Bypass Module EARTH GROUND terminal to

the earth ground wire.

3. Connect the RE-2 EARTH terminal to one of the case ground studs

(this connection is mandatory for lightning protection).

Case Ground

A ground wire connects the front and rear cases together. Be sure
to re-connect this wire before completing the installation. Refer to
Figure 15 for case ground wire attachment details.

OPTIONAL REMOTE ANTENNA

If wireless transmitters are going to be used, a remote antenna must
be installed to provide reception for the RE-2.
Two models of antennas are compatible with the RE-2. The
Model EXA-1000 is a omni-directional antenna. The Model EXA-2000
is a directional antenna used in installations where transmitted
signals are desired to be received only in a particular direction.

NOTE: Up to 50 feet of type RG-59 coax can be used to connect the

antenna to the RE-2. Keep the coax as short as possible.

1. Install the antenna. (See EXA-1000 or EXA-2000 installation

instructions.)

2. Connect the antenna coax cable to the antenna and route the cable to

the RE-2.

3. With the power off, connect the cable to the RE-2’s ANTENNA

connector.

RE-2

TRANSFORMER

TELCO

OPEN #1

KEYPAD GND

KEYPAD DAT 1

KEYPAD DAT 0

KEYPAD PWR

TRANSFORMER

TRANSFORMER

BATTERY NEGATIVE

BATTERY POSITIVE

SENSE #1

COMMON

KEYPAD CLK

KEYPAD DVAL

OPEN #2

RE-2

TERMINALS

SENSE #2

GROUND

STAKE

RING

TIP

RING

TIP

EARTH

HOUSE

NOTE: BACKUP BATTERIES
WILL REQUIRE AN
EXTERNAL CHARGER

TIP

RING

TIP

RING

TIP

RING

TIP

RING

TELCO

RE-2

TELCO

RE-2

HOUSE

HOUSE

TELEPHONE

BYPASS

MODULE

EARTH

GROUND

12 VOLT

1.2 AMP/HR

BATTERY

12 VOLT

1.2 AMP/HR

BATTERY

NOTE: TWO 12-VOLT BATTERIES ARE
RECOMMENDED, ALTHOUGH ONE
12-VOLT BATTERY CAN BE USED

GROUND

STAKE

CASE

GROUND

Figure 16. Power, Backup Battery & Ground Wiring

CONNECT COAX
TO ANTENNA
CONNECTOR

RE-2

CIRCUIT BOARD

OPTIONAL
EXA-2000
DIRECTIONAL
ANTENNA

OPTIONAL EXA-1000

OMNI-DIRECTIONAL

ANTENNA

Figure 17. Remote Antenna Connection

Figure 15. Case Ground Connection

CONNECT INCOMING EARTH GROUND WIRE TO ONE
REAR CASE GROUND STUD WITH A RING TERMINAL

CONNECT THE FRONT
CASE GROUND WIRE
TO THE OTHER REAR
CASE GROUND STUD

CONNECT THE
CIRCUIT BOARD
EARTH GROUND
TERMINAL TO
A CASE GROUND
STUD

IMPORTANT! FOR THE BEST PROTECTION AGAINST LIGHTNING DAMAGE
ALL EARTH GROUND CONNECTIONS MUST BE WIRED AS SHOWN

This manual is related to the following products: