Step 4. FIELD WIRING

Caution: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors
can cause improper and dangerous opera-
tion. Verify proper operation after servicing.

Refer to Section A for millivolt appliances and
Section B for electronic appliances. The gas
valve is set in place and pre-wired at the
factory on both models.

Note:

Secure Flex vent must be attached to

Secure Flex terminations only. DO NOT
substitute

Secure Vent terminations or the

Secure Vent adapter for Secure Flex compo-
nents. The collars of

Secure Flex termina-

tions and adapters have a different circum-
ference than that used with the

Secure Vent

pipe. Additionally,

Secure Flex components

have an extended length center tube for use
in attaching the flexible vent.

A. Millivolt Wiring

(See Figure 36 )

1. Appliance-mounted ON/OFF burner control
switch (rocker switch) is factory installed be-
hind the bottom panel. Optional wall-mounted
switch, thermostat, or one of the optional
remote control kits may also be used.

2. If wall-mounted ON/OFF control or thermo-
stat is selected mount it in a convenient loca-
tion on a wall near the fireplace.

3. Wire the control switch within the millivolt
control circuit using the 15 feet of 2 conductor
wire supplied with the unit.

Note: The supplied 15 feet of 2 conductor
wire has one end of each conductor con-
nected to the gas valve circuit and the other
end of each conductor placed loose inside
the bottom compartment.

Caution: Do Not connect the optional wall
switch to a 120V power supply.

Figure 36

Figure 37

4.If an optional control switch is installed, turn
the appliance-mounted ON/OFF burner con-
trol switch to the OFF position.

B. Electronic Wiring (See

Figure 37 ) –

Note: The electronic appliance must be con-
nected to the main power supply.

1. Route a 3-wire 120Vac 60Hz 1ph power
supply to the appliance junction box.

2. Remove the electrical inlet cover plate from
the side of the unit by removing the plate's
securing screws.

See Figure 11 on page 9.

3. Remove the cover plate's knockout and then
feed the power supply wire through the knock-
out opening and into the unit junction box.

4. Connect the black power supply wire to the
lower outlet's red pigtail lead and the white
power supply wire to the common terminal of
the outlet as shown in

Figure 37.

5. Connect the ground supply wire to the pigtail
lead attached to outlet's green ground screw.

6. Appliance-mounted ON/OFF burner control
switch (rocker switch) is factory installed be-
hind the bottom panel.

Optional wall-mounted switch, thermostat, or
one of the optional remote control kits may
also be used. The appliance mounted ON/OFF
switch needs to be relocated onto the optional
style view door, if used.

7. If wall-mounted ON/OFF control or thermo-
stat is to be used, mount it in a convenient
location on a wall near the fireplace.

8. If an optional control is to be used, wire it in
the low voltage circuit as shown in

Figure 37.

Note: The supplied 15 feet of 2 conductor wire
has one end of each conductor connected to the
gas valve circuit and the other end of each
conductor placed loose inside the bottom com-
partment.

9. If an optional control switch is installed,
turn the appliance-mounted ON/OFF burner
control switch to the OFF position.

10. After the wiring is complete, replace the
cover plate.

Note: No batteries to be installed in the
battery holder until a power outage, or if the
appliance is to be operated solely with two
(2) "D" batteries.

TP-TH

TP

TH

APPLIANCE- MOUNTED
ON/OFF SWITCH

BK/W(1)

BK/W(1)

WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)

WIRING DIAGRAM MILLIVOLT GAS VALVES

THERMOPILE

GAS VALVE

JUNCTION BOX

W

GR

120 VAC

BK

TRANSFORMER 3V

INTERMITTENT ELECTRONIC WIRING DIAGRAM

BROWN

BROWN

BLACK

BATTERY BACK-UP

TO WALL
SWITCH OR
THERMOSTAT

BLACK (SENSOR)

BLACK (IGNITOR)

SPARK TO PILOT IGNITOR

IGNITOR MODULE

3V

RED

BK W GR

PILOT

IN

OUT

VENT

LO

HI

TH

TP

TH

TP

IN

ORANGE (THTP)

BLACK (TP)

GREEN (TH)