REFRIGERANT CHARGE
(*) Refrigerant charge R-22 precharge from factory on the outdoor unit.
(**) Meter of installation line where outdoor unit is precharged+charge also to the group
(***) If line is different to meters indicated on table put more or less charge of refrigerant per meter indicated.
Charge precharge on outdoor unit
Charge per line
55gr/m x (6-5)m
=
=
5300
55
Total charge of the installation
=
5355 gr
If you need to install a group WING 5CFK, with distance of line between indoor and outdoor unit of 6 meter. The
refrigerant charge R-407C needed in the installation is:
EXAMPLE: