3 - Turn off all electrical power to the unit.

4 - This unit is equipped with an ignition device which auĆ

tomatically lights the burners. Do not try to light it by

hand.

5 - Remove the unit access panel.

6 - Turn gas valve knob to OFF. See figure 3.

Figure 3

HONEYWELL VR8205 Series Gas Valve

Gas Valve Shown In OFF Position

manifold

pressure

tap

high fire adjusting screw

(under cap)

low fire

adjusting screw

(under cap)

inlet pressure tap

7 - Wait five (5) minutes to clear out any gas. If you then

smell gas, STOP! Immediately call your gas supplier

from a neighbor's phone. Follow the gas supplier's inĆ

structions. If you do not smell gas go to next step.

8 - Turn gas valve knob to ON. Do not force the knob.
9 - Replace the unit access panel.
10 - Turn on all electrical power to the unit.
11 - Set thermostat to desired setting.

NOTE - When the unit is first started, steps 1 through
11 may need to be repeated to purge air from pilot line.

12 - If the appliance still will not operate, follow the instrucĆ

tions Turning Off Gas to the Unit" and call your service

technician or gas supplier.

Turning Off Gas to the Unit
1 - Set thermostat to lowest setting.

2 - Turn off all the electrical power to unit if service is to be

performed.

3 - Remove the unit access panel.

4 - Turn gas valve knob to OFF. Do not force the knob.

5 - Replace the unit access panel.

Filters

A filter must be in place anytime the unit is operating. The

filter may be located in the unit or installed in a return air

grille. Ask your dealer to show you the filter location. The

filter should be inspected monthly and cleaned when necĆ

essary to assure proper that the furnace operates properly.
Filters used inside the GHR32 series units are available

from Lennox and must be ordered separately. These foam

filters may be cleaned for reuse. If the filters need to be reĆ

placed, order Lennox part #31J81 for 14 X 25 inch filters for

the GHR32Q-50, -75 and GHR32V-75. Number P-8-7831

is for 20 X 25 inch filters which are used with the GHR32Q,

and V-100 and the GHR32Q-120 units. See figure 4 for reĆ

moving the filter from the unit. Use the following procedure

to clean the filter.

Figure 4

Press up on side filter clip to

release filter

(One on each side of cabinet)

FILTER

CABINET

FILTER

CLIP

BACK FILTER CLIP

FILTER

SIDE FILTER

CLIP DETAIL

CABINET

FILTER

CLIP

Cleaning Filter

1 - Turn off electric power to the unit.
2 - Remove blower access panel.
3 - Remove filter by pressing side filter clips and pulling

filter up and out.

4 - Clean filter with cold water and a mild soap. Direct waĆ

ter through filter in the opposite direction of air flow.

Remove all soap residue.

5 - Allow the filter to dry, then spray with Filter HandicoatĆ

er (P-8-5069) prior to reinstallation. This spray is availĆ

able from your Lennox dealer.

6 - Replace the filter in the blower compartment under the

rear filter clip. Press on filter sides. The filter clips flex,

allowing filter to snap into place.

7 - Replace the blower access panel.

WARNING

Blower door must be securely in place when blower

and burners are operating. Gas fumes, which could

contain carbon monoxide, can be drawn into living

space resulting in personal injury or death.

Seasonal Inspections

A qualified service technician should inspect the complete

system each season (heating and cooling). The following

maintenance procedures should be conducted by a

qualified service technician. Do not attempt to service

the unit in any way.
During a seasonal check the service technician will inspect

the indoor blower and the burner flames along with the

venting system.
Venting System

Annually (before heating season) inspect furnace venting

system, heat exchanger, and burners for corrosion, deteriĆ

oration, or deposits of debris. Remove any obstructions.
Inspect furnace venting system to make sure it is in place,

physically sound, and without holes or blockage. Vent conĆ

nector must be in correct position, sloped upward and be

physically sound without holes.