Lantronix Hub User Manual
Page 17

MSS User Guide
2: Installation
2-6
MSS-VIA Specifications
Power (power cube adaptor)
Adapter:
Input:
100-240 VAC Universal Power Supply with International
Adapters
Output:
12 VDC Max
Current:
1A @ 12 V
MSS-VIA power input range:
7-24 VDC
Temperature
Note:
Rapid temperature changes may affect operation. Do not operate near heating or
cooling devices or areas that open to the outdoors.
Operating range:
5° to 50° C (41° to 122° F)
Storage range:
40° to 66° C (-40° to 151° F)
Max. temp change:
20° C (36° F) per hour
Humidity
Operating range:
10% to 90% non-condensing
40%
to
60%
recommended
Storage range:
10% to 90% non-condensing
Altitude
Note:
For operations above 2.4 km (8,000 ft), decrease the operating temperature rating
by 1.8°C for each 1,000 m (1°F for each 1,000 ft).
Operating
2.4 km (8,000 ft)
Storage
9.1 km (30,000 ft)