Fireplace insert installation, Minimum clearances, Insert placement requirements – Lopi Answer Wood Stove User Manual
Page 19: Hearth requirements, Masonry fireplace requirements
Fireplace Insert Installation
(for qualified installers only)
19
© Travis Industries
100-01166
4040907
Insert Placement Requirements
•
The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" of the front of the insert
•
Insert and hearth must be installed on a level, secure floor
•
The minimum clearances, facing, and hearth requirements in Figure 17 must be met (follow the
clearances for the type of fireplace being used - either masonry or zero-clearance).
Side
Wall
Combustible Mantel
Combustible Top Facing
Non-Combustible
Hearth
Facing
Masonry
Fireplace
Minimum Clearances
k
l
m
n
o
p
q
x
Sidewall to Insert
Side Facing
Top Facing
Mantel to Insert
Hearth (Front)*
Hearth (Side)
Front of Insert
Extension onto Hearth
13"
9-1/2"
12"
15-1/2"
16"
8"
36"
3"
* Does not include the distance the insert
extends onto the hearth (dimension "x").
q
l
k
p
x
o
n
m
ZC (Metal)
Fireplace
30"
12"
12"
24"
16"
8"
36"
3"
Figure 17
Hearth Requirements
•
Must extend 16" in front of the insert and 8" on both sides (min. 19" deep by 39-5/8" wide)
•
Must be non-combustible and at least .018" thick (26 gauge)
Masonry Fireplace Requirements
•
Chimney must have a clay tile liner or a stainless steel liner (positive connection)
•
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert
•
Chimney height: 15' minimum; 33' maximum.
•
Entire fireplace, including chimney, must meet local building requirements