Lytecaster performance recessed downlighting – Lightolier 1101 User Manual
Page 3

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • B1010
Lytecaster Performance Recessed Downlighting
1101
Page 3 of 3
6 ¾" Aperture Vertical Open, Performance Series, Reflector Trim
Job Information
Type:
1101CL HID 100W ED-17 LAMP
1000
2000
3000
1000
2000
3000
60˚
30˚
Coefficients Of Utilization
Ceiling
80%
70%
50%
30%
0
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 74 74 74 74 72 72 69 69 66 66 62
1 69 67 66 64 66 63 64 61 61 59 56
2 65 62 59 56 60 55 58 54 57 53 51
3 61 56 52 50 55 49 54 48 52 48 46
4 57 51 47 44 51 44 49 43 48 43 41
5 53 47 43 39 46 39 45 39 44 38 37
6 50 43 39 35 43 35 42 35 41 35 34
7 47 40 35 32 39 32 38 32 38 32 30
8 44 37 32 29 36 29 35 29 35 29 28
9 41 34 30 27 34 27 33 26 32 26 25
10 39 31 27 24 31 24 31 24 30 24 23
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts =
Candlepower Distribution
Angle
Mean CP
0
2519
5
2547
10
2597
15
2685
20
2747
25
2736
30
2526
35
2135
40
1729
45
1302
50
792
55
284
60
26
65
7
70
4
75
4
80
2
85
2
90
1
Trim/Frame:
1101CL
Lamp lumens:
7900 lm
Input Watts:
119 W
Efficiency:
62.0 %
Spacing Criterion:
1.36
Multiple Unit Data - RCR 2
Spacing
Avg.Initial
Watts/
On Ctr.
Footcandles
Sq. Ft.
6'
121
2.97
8'
84
2.06
10'
54
1.32
38'x38'x10' Room, Workplane 2 1/2'
above floor, 80/50/20% Reflectances
Single Unit Data
Height to
Initial
Beam
Lighted Plane
Footcandles
Diameter
6'
70
8'
8'
39
11'
10'
25
14'
12'
17
16'
Zonal Lumens And Percentages
Zone
Lumens
%Luminaire
0-30
2253
46.0%
0-40
3582
73.0%
0-60
4864
100.0%
0-90
4878
100.0%
CERTIFIED TEST REPORT NO. 4051FR