TROUBLE SHOOTING GUIDE

GAS OVENS

MODELS 1152 - 1153 - 1154 - 1155 - 1156 - 1157 - 1158

REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Oven fan will not run

Incoming Power Supply

Check circuit breakers, reset if

required, call power company if needed.

Main Fan Switch

Check continuity between switch

terminals.

Control Box High Limit

Terminals are normally closed, and

Thermostat

open at 170°F ± 5F (76.6°C ± 2.8°C).

NOTE: Discontinued at

Check for over heating and reset

S/N 2011821

thermostat. Test for proper

operation. If it will not reset and hold, re-

place thermostat.

Fuse, 1 Amp

Check, replace if necessary.

Fuseholder

Check, replace if necessary.

Transformer,Step Down

120 VAC ± 10% should be present at

secondary of transformer. If proper

voltage is not present, check

transformer primary for proper

input. Replace as needed.

Oven Start Relay

Check for 120 VAC to relay coil. If

voltage is not present, trace wiring

back to power source. If voltage is

present, check to insure contact

is closing.

20 Minute Time Delay

Check for 120 VAC at terminal #1 to

neutral on 20 minute Time Delay

Relay. If no voltage is present, trace

wiring back to power source.

If voltage is present at terminal #1,

check for 120 VAC at terminal #2 to

neutral. If no voltage is present, and

cool down relay contact is closed,

replace Time Delay Relay.

Main Fan Relay

Check for 120 VAC to coil of the Relay

if no voltage is present, trace wiring

back to 20 minute Time Delay Relay.

If voltage is present, check to insure

contacts are closing.

Fuse, 10 Amp

Check, replace if necessary.

Fuseholder

Check, replace if necessary.

Motor Capacitor

Check for opens, shorts, or grounds.

Main Fan Motor

Check for supply voltage to main fan

motor. If voltage is not present, trace

wiring back to main fan relay. Check for

opens, shorts, or grounds.

WITH POWER OFF: turn fan blade to

check for locked rotor.