beautypg.com

Fcc compliance, Operation troubleshooting – Leviton Scene Capable Electronic Switch User Manual

Page 2

background image

DI-000-RZS15-00A-X3

• Position all wires to provide room in outlet wall box for device.
• Ensure that the word “TOP” is facing up on device strap.
• Partially screw in mounting screws in wall box mounting holes.
NOTE: Dress wires with a bend as shown in diagram in order to

relieve stress when mounting device.

• Restore power at circuit breaker or fuse.
• Press pad until locator light is OFF. Lights should turn ON.
If lights do not turn ON, refer to the TROUBlESHOOTING section.

lIMITED 5 YEAR WARRANTY AND EXClUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,

at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 little Neck Parkway, little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability

for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or

implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. leviton is not liable for incidental,

indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

Testing your Switch prior to mounting in wall

box:

Step 5

Step 6

Including Switch into Z-Wave

TM

Network:

NOTES:

If using a non-Leviton Programmer/Controller, refer to the Programmer/

Controller instruction sheet for Including a device.

A) If using a Leviton Z-Wave

TM

Programmer/Controller, Cat. No. RZCPG,

press the Menu button and scroll down to System Setup. Press the

center button to select System Setup Menu. Press the center button to

select Network.

B) While standing close to the

switch (approximately 2-5

ft.), press the center button

to device in the

network.

NOTE: Only one device may

be included at a time. DO

NOT put multiple devices into

the Inclusion mode at any

time.

C) While the Programmer/

Controller is in the Inclusion

mode and the Locator LED

is ON on the switch, press

the push pad to turn on the

switch. The Programmer/

Controller will verify inclusion

and the Locator LED will turn

OFF.

If the switch is flashing Amber

while in the Inclusion mode,

the Programmer/Controller is still trying to communicate with the switch.

Wait until the device stops flashing, then press the push pad.

NOTE: If the Locator LED on the switch turns solid Red while including,

there has been a communication error. Refer to Troubleshooting

section.

D) The Primary Programmer/Controller will assign a node ID number

(Name) for this device.

NOTE: This ID number (Name) will be stored in the controller to be

used for future reference.

NOTE: You may name or edit the node of this device at this time.

E) The switch is now installed in the network.

NOTE: If the switch has been successfully Included in the network and the

user tries to Include it again without first excluding it from the network, the

switch will retain the first node ID it had received and ignore the second.

Programmer/Controller

Cat. No. RZCPG

NOTE: Programmer/Controller must

be in close proximity to switch when

including in the network.

Step 7

Excluding Switch from Z-Wave

TM

Network:

For additional information, contact leviton’s

Techline at 1-800-824-3005 or visit leviton’s

website at www.ViziaRF.com

U.S. & Foreign Patents Pending

Copyright© 2006 Leviton Manufacturing Co., Inc.

All Rights Including Trade Dress Rights Reserved

This equipment has been tested and found to comply with the limits for

a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These

limits are designed to provide reasonable protection against harmful

interference in a residential installation. This equipment generates, uses,

and can radiate radio frequency energy and, if not installed and used in

accordance with the instructions, may cause harmful interference to radio

communications. However, there is no guarantee that interference will

not occur in a particular installation. If this equipment does cause harmful

interference to radio or television reception, which can be determined

by turning the equipment OFF and ON, the user is encouraged to try to

correct the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to

which the receiver is connected.

• Consult the dealer or an experienced radio/tv technician for help.

FCC COMPlIANCE

STATEMENT

Push

Pad

locator

light

NOTE: The locator light will illuminate when

the load is in the OFF position to facilitate

access in the dark.
Push Pad (Default settings)
Turn ON from OFF position:

Tap – Lights turn ON.
Turn OFF from ON position:

Tap – Lights turn OFF.
If there is a power outage, when the power

is restored, the lights will return to the last

setting before the power interruption.
Cleaning: Clean with a damp cloth. DO

NOT use chemical cleaners.

OPERATION

TROUBlESHOOTING

• lights Flickering
- Lamp has a bad connection.

- Wires not secured firmly under terminal screws of switch

and/or remote.

• light does not turn ON and locator lED does not turn ON
- Circuit breaker or fuse has tripped.

- Lamp is burned out.

- Lamp Neutral connection is not wired.
• Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft (90 m).

Restore Power:

Restore power at circuit breaker or fuse.

Installation is complete.

Step 9

Switch Mounting:

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

Step 8

Installation may now be

completed by tightening

mounting screws into wall

box. Attach wallplate.

NOTE: It is very important to accurately Exclude devices from the network

when moving or removing a device from a Z-Wave

TM

network. This ensures

that all information has been removed from your Primary Programmer/

Controller's information table and is not counted on to be part of the mesh

network.
A) If using a Leviton Z-Wave

TM

Programmer/Controller, Cat. No. RZCPG,

press the Menu button and scroll down to System Setup. Press the

center button to select System Setup Menu. Press the center button to

select Network.

B) While standing close to the switch (approximately 2-5 ft.), press the

center button to device from the network.

C) While the Programmer/Controller is in the Exclusion mode and the

locator LED is ON on the Dimmer, press the push pad to turn on the

switch. The Programmer/Controller will verify Exclusion and the locator

LED will turn OFF.

If the switch is flashing Amber while in the Exclusion mode, the

Programmer/Controller is still trying to communicate with the switch. Wait

until the device stops flashing, then press the push pad.

Factory Default:

If your switch is not responding, or you are unable to control it after you

have tried to Include/Exclude it multiple times, it may be necessary to reset

the switch to its original factory settings. To

accomplish this, proceed as follows:
• On the switch, engage the air-gap switch

by gently pulling the bottom of the push pad

until it lifts completely out of the frame and

a click is heard. (refer to figure). Wait 5

seconds and then press the push pad back

into the frame and hold push pad until the

locator LED flashes Amber and turns solid

Red. The switch is now reset. Once the

switch is reset, it will be necessary to Re-

Include it to a network before it can be used.

CAUTION:

SETTING A DEVICE TO A

FACTORY DEFAULT DOES NOT EXCLUDE

THAT DEVICE FROM A NETWORK. THE

EXCLUSION PROCEDURE MUST STILL BE

FOLLOWED TO REMOVE THE DEVICE FROM

THE PRIMARY CONTROLLER’S INFORMATION TABLE. FAILURE TO DO

SO MAY RESULT IN SYSTEM THAT IS SLOW TO RESPOND, OR MAY

FAIL TO RESPOND TO SOME DEVICES.

Gently lift bottom of

push pad out

1

ON

2

ON

3

ON

4

ON

OFF

OFF

OFF

OFF

Programmer/Controller

Cat. No. RZCPG

Menu Button

Center Button

WIRING COORDINATING REMOTE:

Connect wires per WIRING DIAGRAM as follows:

NOTE: "BK" and "RD" terminals on coordinating remote are unused.

Tighten both screws.

NOTE: Maximum wire length from switch to last remote is

300 ft (90 m).

• Green or bare copper wire in wall box to Green terminal screw.

• Load wall box wire identified (tagged) when removing old switch to

First Traveler (note color as above).

• Second Traveler wall box wire (note color as above) to terminal

screw marked "YL/RD". This traveler from the remote must go to the

terminal screw on the switch marked "YL/RD".

• Remove White insulating label from terminal screw marked "WH".

• Line Neutral wall box wire to terminal screw marked "WH".

• Proceed to Step 5.