Lacie 12big rack serial, Quick install guide, I/o module – LaCie 12big rack Serial User Manual
Page 9: Page 9

LaCie 12big rack serial
I/O Module
Quick Install Guide
page 9
ops Panel LEDs
other
associated LEDs or alarms
State Description
P
ower
o
n
(g
reen)
System Fault
(a
mber)
Logical Fault (a
mber)
3
Bo
x
identify
(Blue)
On
On
On
On
12big rack serial Module activity LEDs flash
Ops Panel power on test state.
On
Off
any
any
Power On. All functions good.
On
On
any
any
Dual Fan Cooling Module Fault LED on.
Continuous beep.
Dual Fan failure.
On
Flash
any
any
Dual Fan Cooling Module Fault LED on.
Intermittent beep.
Single Fan failure.
On
Flash
any
any
PSU Module Fault LED on.
Intermittent beep.
Single PSU failure.
On
Flash
any
any
Intermittent beep.
PSU removed.
On
Flash
any
any
Intermittent beep.
Over or under temperature warning.
On
On
any
any
Continuous beep.
Over or under temperature critical.
On
On
any
any
Continuous beep.
Voltage critical.
On
Off
As per Drive fault
LED
any
None
Drive critical.
On
Off
As per Drive fault
LED
any
None
Drive non-critical.
On
On
any
any
12big rack serial Fault & ID LEDs on.
Continuous beep.
12big rack serial Module watchdog failure.
On
Flash
any
any
2
12big rack serial Fault & ID LEDs on.
Internittent beep.
12big rack serial Module soft (or POST)
failure.
On
Flash
any
any
2
12big rack serial Fault & ID LEDs on.
Intermittent beep.
Other 12big rack serial Module fault.
LED operation set via SES Control page 0x02
On
any
Off
any
Power On. All functions good.
On
any
As per Drive fault
LED
any
Drive Bay Fault LED flash.
POST fault bit set for any Array Device
Element.
On
any
As per Drive fault
LED
any
Drive Bay Fault LED flash.
Other Array bits set for any Array Device
Element.
On
On
any
any
Continuous beep.
UNRECOV bit set in Audible Alarm element.
On
any
any
any
Intermittent beep.
INFO, NON-CRIT, CRIT bits set in Audible
Alarm element
On
any
any
any
Continuous beep.
UNRECOV bit set in Audible Alarm element.
On
Flash
any
any
REQUEST WARNING bit set in Enclosure
element.
On
On
any
any
REQUEST FAILURE bit set in Enclosure
element.
On
any
any
Flash
RQST IDENT bit set in Enclosure element.
notes
The 12big rack serial alarm pattern is a 1 second on, 1
1.
second off sequence, applied to all 12 Activity LEDs.
If an 12big rack serial fault LED is fitted, this will be set for
2.
all the above conditions. In addition this LED will flash for
an 12big rack serial module soft failure.
The Logical Fault LED will take the state of the highest
3.
priority drive bay fault LED.