Aletta al1t8, Lighting systems, Performance – Lightolier ALETTA AL1T8 User Manual
Page 2: Mounting accessory, Em pack output table

Job Information
Type:
631AirportRoad,FallRiver,MA02720•(508)679-8131•Fax(508)674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com©2010PhilipsGroup•
Lighting Systems
ALETTA AL1T8
Page 2 of 2
LouverShield,1T8LampperFixture,GridMounted
D1007
Performance
COEFFICIENTS OF UTILIZATOIN
% EFFECTIVE CEILING CAVITY REFLECTANCEE
CANDLEPOWER CURVE
80
70
50
WALL REFLECTANCE
70 50 30
70 50 30
50 30 10
0 76 76 76
74 74 74
71 71 71
1 70 67 64
68 65 63
63 61 59
2 64 59 55
62 58 54
56 53 50
3 59 53 48 57 52 47
50 46 43
4 54 47 42
53 47 42
45 41 38
5 50 43 38
49 42 37
41 37 33
6 47 39 34
46 38 34
37 33 30
7 44 36 31
43 35 30
34 30 27
8 41 33 28
40 33 28
32 27 24
9 39 31 26
38 30 25
29 25 22
10 36 28 24
36 28 24
27 23 20
20% FLOOR CAVITY REFLECTANCE
Zone
Lumens
% Lamp
% Luminaire
0-90
1872
63.4
100
0-180
1872
63.4
100
DISTRIBUTION
Mounting Accessory
Drywall Conversion Kit
For Individual Units only
FK92X2
FK92X4
Lamp
Length
Lamp
Type
Lamp Rated
Output
Lamp
Wattage
Battery
Lumen Output
T5HO
4450*
54
1250*
T5
2600*
28
1325*
T8
2950
32
1100
T5HO
1750*
24
725*
T5
1200*
14
750*
T8
1350
17
650
* 25˚C Rating
CANDLEPOWER
ZONE
0
22
45
67
90
DEG.
CANDELAS
90
0
0
0
0
0
85
16
25
23
20
19
75
69
81
117
149
154
65
143
145
161
201
217
55
278
242
240
250
262
45
501
444
328
321
327
35
665
661
532
435
416
25
802
812
781
725
694
15
903
907
921
920
914
5
965
964
963
961
960
0
967
967
967
967
967
REPORT NO.: ALE41T8.IES
LAMPS: 1 FO32/835
LUMENS: 2950
EFFICIENCY: 63.4%
EM Pack Output Table
ROOM CAVITY RATIO
– Conversion Kit for 2’ (60.96cm) Unit
– Conversion Kit for 4’ (121.92cm) Unit
4’
(121.92cm)
4’
(121.92cm)
4’
(121.92cm)
2’
(60.96cm)
2’
(60.96cm)
2’
(60.96cm)