Part 3

ELECTRICAL CONNECTIONS

Follow the instructions under “

4

CONNECT RANGE

CORD” on page 5 to correctly install the strain relief.
1. Remove the lower 3 screws from the terminal block

and retain them. (Refer to Figure 9.)

Remove the ground screw and retain it.

2. Remove ground strap and discard as shown

in Figure 9.

Do not discard any screws.

3. Insert the ground screw into the power cord ground

wire terminal ring and secure it to the range frame.

4. Insert the 3 screws through each power cord

terminal ring and into the lower terminals of the

terminal block. Make sure that the center wire

(white/neutral) is connected to the center lower

position of the terminal block.

Tighten 3 screws securely into the terminal block.

5. Go to page 10.

Install the conduit as follows:

Remove the Conduit connection plate from the rear of

lower oven and rotate it as shown in Figure 5. The

conduit hole (1

1

/

8

”) must be used.

First, prepare the conduit wires as shown in Figure 10.

Second, install conduit as shown in Figure 6.
For conduit installations, after purchasing a strain

relief, insert it in the conduit hole (1

1

/

8

”). Then install

the conduit through the body of strain relief and

fasten the strain relief with its ring. Reinstall the

bracket.
For conduit connections :

If the wire in the conduit is copper it must be 8 or 10

AWG wiring.

If the wire in the conduit is aluminum it must be 6 or 8

AWG wiring.
1. Loosen the lower 3 screws from the terminal block.

(Refer to Figure 11.)

2. Insert the bare wire (white/neutral) end through the

center terminal block opening.

Do not remove ground strap connections.

3. Insert the two side bare wire ends into the lower left

and the lower right terminal block opening.

Tighten the 3 screws securely into the terminal block.

(approximately 35 - 50 IN-LB)

4. Go to page 10.

FIGURE 10

or

3 wire

4 wire

FIGURE 9

4-wire connection

WARNING

• Only a 4-conductor power-supply cord kit

rated 120/240 volts, 50 amperes and

marked for use with ranges with closed-

loop connectors or open-end spade lugs

with upturned ends shall be used. The

middle (neutral) wire of the power cord or

4-wire conduit has to be connected to the

middle post of the main terminal block.

The other two wires of the power cord or

conduit have to be connected to the

outside posts of the main terminal

connection block. The 4th ground wire

must be connected to the frame of the

range with the ground screw.

- Failure to do so can result in electrical shock, severe

personal injury or death.

Gloves

Safety Glasses

Tape Measure

Pencil

Rear filler & 2 Screws

(LSE Series only)

FIGURE 11

3-wire connection

4-wire connection with a power supply cord

3-wire connection: conduit

This manual is related to the following products: