Installation, General, Ambient conditions – Lincoln Electric 3.1 User Manual
Page 8
500
750
4
6
0
250
1000
2
0
Air Flow (CFM)
Vacuum
(Inches WG)
SF 2400
LTA 3.1/4.1
PRESSURE DROP - SF2400 Fan
and LFA 3.1/4.1 Arms
LFA 3.1 & 4.1 FUME EXTRACTION ARMS
A-1
INSTALLATION
A-1
Technical Specifications- LFA 3.1 & 4.1 Fume Extraction Arms
NOTE: Technical Specifications are subject to change without prior notice. Specifications and guarantees are
valid only when specified spare parts and filters are used.
Sales Specification
K1655-1
K1655-2
Description
LFA 3.1, 10 ft. Extraction Arm
LFA 4.1, 13 ft. Extraction Arm
Arm Length (including hood)
9.85 ft. (3 m)
13.13 ft. (4 m)
Nominal Diameter
8.0 in. (203 mm)
Recommended Capacity
350 CFM (600 m3/h) - 940 CFM (1,600 m3/h)
Weight
33 lbs. (15 kg)
37 lbs. (17 kg)
GENERAL
Min. Temperature
41
o
F (5
o
C)
Max. Temperature
113
o
F (45
o
C)
Max. Rel. Humidity
80%
AMBIENT CONDITIONS
0 ft.
3 ft.
6 ft.
10 ft.
13 ft.
0 ft.
3 ft.
6 ft.
10 ft.
13 ft.
16 ft.
0 ft.
3 ft.
6 ft.
10 ft.
13 ft.
0 ft.
3 ft.
6 ft.
10 ft.
13 ft.
16 ft.
20 ft.