beautypg.com

Installation, General, Ambient conditions – Lincoln Electric 3.1 User Manual

Page 8

background image

500

750

4

6

0

250

1000

2

0

Air Flow (CFM)

Vacuum
(Inches WG)

SF 2400

LTA 3.1/4.1

PRESSURE DROP - SF2400 Fan

and LFA 3.1/4.1 Arms

LFA 3.1 & 4.1 FUME EXTRACTION ARMS

A-1

INSTALLATION

A-1

Technical Specifications- LFA 3.1 & 4.1 Fume Extraction Arms

NOTE: Technical Specifications are subject to change without prior notice. Specifications and guarantees are
valid only when specified spare parts and filters are used.

Sales Specification

K1655-1

K1655-2

Description

LFA 3.1, 10 ft. Extraction Arm

LFA 4.1, 13 ft. Extraction Arm

Arm Length (including hood)

9.85 ft. (3 m)

13.13 ft. (4 m)

Nominal Diameter

8.0 in. (203 mm)

Recommended Capacity

350 CFM (600 m3/h) - 940 CFM (1,600 m3/h)

Weight

33 lbs. (15 kg)

37 lbs. (17 kg)

GENERAL

Min. Temperature

41

o

F (5

o

C)

Max. Temperature

113

o

F (45

o

C)

Max. Rel. Humidity

80%

AMBIENT CONDITIONS

0 ft.

3 ft.

6 ft.

10 ft.

13 ft.

0 ft.

3 ft.

6 ft.

10 ft.

13 ft.

16 ft.

0 ft.

3 ft.

6 ft.

10 ft.

13 ft.

0 ft.

3 ft.

6 ft.

10 ft.

13 ft.

16 ft.

20 ft.

This manual is related to the following products: