Fireplace specifications – Lennox Hearth OASIS SERIES LSO-43 User Manual
Page 6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
6
FIREPLACE SPECIFICATIONS
Figure 9
Step 3. Refer to fireplace drawings and speci-
fications on pages 6 and 7 for framing dimen-
sions and details. Frame appliance enclosure as
illustrated in
Figures 10 through 13 on page 7.
IMPORTANT: UNDER NO CIRCUMSTANCES
CAN THE FIREPLACE TOP SPACERS (
FIGURE
9 ) BE REMOVED OR MODIFIED, NOR MAY
YOU NOTCH THE HEADER TO FIT AROUND
OR BE INSTALLED LOWER THAN THE SPAC-
ERS. THE HEADER MAY BE IN DIRECT CON-
TACT WITH THE TOP SPACERS BUT MAY NOT
BE SUPPORTED BY THEM.
Figure 8
Figure 7
11"
(279mm)
49
⁵⁄₈"
(1260mm)
31" (788mm)
9
³⁄₄"
(248mm)
¹⁄₂" (13mm)
Front View
51
¹⁄₈"
(1299mm)
6
¹⁵⁄₁₆"
(176mm)
1
⁹⁄₁₆"
(40mm)
¹⁄₂"
(13mm)
42
³⁄₄" (1086mm)
24
¹⁄₁₆"
(611mm)
4
³⁄₁₆"
(106mm)
¹⁄₂"
(13mm)
25
¹⁄₈"
(638mm)
5
¹⁄₁₆"
(129mm)
11
⁵⁄₁₆"
(287mm)
8
⁵⁄₈"
(219mm)
52
¹⁄₄" (1327mm)
39
¹¹⁄₁₆"
(1008mm)
4
¹⁄₂"
114mm)
Side View (Left)
Top View
44
⁵⁄₈"
(1133mm)
12
⁷⁄₁₆"
(316mm)
39
¹¹⁄₁₆"
(1008mm)
9
¹⁵⁄₁₆"
(252mm)
1
⁹⁄₁₆
"
(40mm)
1
¹⁄₄"
(32mm)
Drain
Plug
11
⁵⁄₁₆"
(287mm)
Metal Safety Strips
with
¹⁄₂" (13mm) Min.
Overlap
1
¹⁄₂"
(38mm)
The safety strips should extend from front of
the fireplace at least 1
¹⁄₂" and should extend to
be at least flush with the sides. In the event a
wooden support is used to elevate the fireplace
above the floor, a “Z” type safety strip should be
fabricated and used to protect the front surface
of the wood support as well as the floor beneath
the hearth extension (
Figures 7 and 8 ). The
safety strips should be tacked down to prevent
possible movement.
Note: The “Z” type safety strip is not supplied.
Special “Z” Metal Safety
Strips with
¹⁄₂" (13mm) Min.
Overlap
2"
(51mm)
Blocking
Note: Safety strips are not required when fire-
place rests on a noncombustible surface.
Note: Install the hearth extension only as illus-
trated (see Figures 41 and 42 ).