beautypg.com

Linear DXSR-1508 User Manual

Supervised digital receivers, Installation instructions, Product description

background image

INSTR, INSTL, DXSR-1504/1508
Linear P/N: 215633 E
Material: 20 Lb. Mead Bond
Size: 8.500" x 11.000"
Ink: Black
Scale: 1-1
Side 1 of 2

DXSR-1504
DXSR-1508

SUPERVISED
DIGITAL RECEIVERS

Installation Instructions

PRODUCT DESCRIPTION

The DXSR-1504 and DXSR-1508 are four and eight channel supervised digital receivers with solid state outputs designed
for use with Linear’s DX and DXS Format transmitters. These receivers can be used in a variety of security and remote
control applications. When the receiver detects a signal from a transmitter programmed into its memory, the appropriate
channel output activates. The channel outputs have three optional configurations; momentary, toggle on/off, and latch until
restored. Status and low battery outputs are for supervisory indications. Cutting jumpers select which channels require
supervisory status reports from transmitters.
Each unit incorporates a dual high-sensitivity superheterodyne diversity receiver with two whip antennas. This type of
receiver provides superior performance by preventing loss of signal due to multi-path interference.
In a typical installation, the receiver is connected to an alarm control panel, door strike, camera, high current relay or some
other devices. Transmitters are used to activate or control the devices. The receiver should be mounted indoors or inside
a weather resistant non-metallic housing for outdoor use.
The digital DX/DXS code format features over a million possible codes. The transmitters are precoded at the factory to
unique codes, so no field coding is required. For versatility, any transmitter can be programmed into any receiver channel.
Receivers must be programmed to recognize the transmitter’s code before system testing and operation. Up to 32
transmitters can be programmed into the receiver. Each button on multi-button portable transmitters send a unique code,
and are programmed as separate transmitters.
The CHANNEL display shows the channels activated and the presence of radio activity. Individual indicators for ALARM,
STATUS, and LOW BATT show the supervisory status of each receiver channel. All outputs can be configured for normally
open or normally closed.
The units can be powered from a 10.2-14.4 VDC or 12-16 VAC power source. The units will draw about 35 mA standby
and up to 120 mA in alarm.

FEATURES

COMPONENT LOCATIONS

OPTION JUMPERS AND CHANNEL BUTTONS DETAIL

MOUNT RECEIVER

ATTACH ANTENNAS

CONNECT TERMINALS

(760) 438-7000 • FAX (760) 438-7043

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

CHANNEL BUTTON

ACCESS PANEL

CHANNEL

DISPLAY

STATUS

INDICATORS

CASE LOCKING

SCREW

OPEN CASE TO

VIEW COMPONENTS

LEFT ANTENNA

TERMINAL

CHANNEL

DISPLAY

ALARM

INDICATOR

STATUS

INDICATOR

LOW BATTERY

INDICATOR

RADIO ACTIVITY

INDICATOR

RIGHT ANTENNA

TERMINAL

AUDIO TEST

POINT

GROUND

TEST POINT

OUTPUT POLARITY

JUMPER

PROGRAM

JUMPER

TERMINAL

BLOCK

WIRING STRAIN

RELIEF POSTS

RECESSED WIRING

ACCESS HOLE

CHANNEL
BUTTONS

OUTPUT

JUMPERS

STATUS

JUMPERS

CHANNEL 1

CHANNEL 2

CHANNEL 3

CHANNEL 4

CHANNEL 5

CHANNEL 6

CHANNEL 7

CHANNEL 8

DXSR-1508 ONLY

CHANNEL

BUTTON

OUTPUT
JUMPER

STATUS

JUMPER

CHANNEL BUTTONS ARE USED DURING PROGRAMMING AND
TO UNLATCH THE CHANNEL'S OUTPUT IN LATCHED MODE

OUTPUT JUMPERS SELECT MOMENTARY, TOGGLE, OR
LATCHED OUTPUT FOR EACH CHANNEL

WHEN A CHANNEL'S STATUS JUMPER IS CUT, THE CHANNEL
WILL REQUIRE STATUS TRANSMISSIONS FROM A SUPERVISED
TRANSMITTER PROGRAMMED INTO THAT CHANNEL

MOUNT RECEIVER AS HIGH
AS PRACTICAL USING
THE SCREWS AND SCREW
ANCHORS PROVIDED

COVER THE SCREWS WITH THE
FOUR SCREW HOLE PLUGS PROVIDED

INSTALL THE TWO
ANTENNAS UNDER THE
LEFT AND RIGHT
ANTENNA TERMINALS

TIGHTEN ANTENNA TERMINALS WITH
ANTENNA WHIPS BELOW THE SCREW
AND UNDER THE TERMINAL PLATE
AS SHOWN (BE SURE TOP COVER SLOTS
ALIGN WITH ANTENNAS)

GND

+12V

LOW BAT

STAT

CH1

CH2

CH3

CH4

GND

CH5

CH6

CH7

CH8

GND

MODEL DXSR-1508 ONLY

SECURE WIRES WITH ZIP-TIE

FROM POWER SOURCE

10.2-14.4 VDC OR 12-16 VAC

120 mA MINIMUM

OUTPUTS TO DEVICE TO BE TRIGGERED

100 mA MAXIMUM PER OUTPUT

WITH OUTPUT POLARITY JUMPER IN
PLACE, ALL OUTPUTS WILL SWITCH
TO GROUND WHEN ACTIVE

NOTE: SEE WIRING EXAMPLES ON
REVERSE SIDE OF THESE INSTRUCTIONS

This manual is related to the following products: