ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTION

REQUIREMENTS

This appliance must be installed and grounded on a
branch circuit by a qualified technician in accordance
with the National Electrical code ANSI/NFPA NO. 70 -
latest edition.
All wiring should conform to Local and NEC. This range
requires a single-phase, 3 wire, A.C 120/208V or 120/240V
60Hz electrical system. Use only a 3-conductor or a
4-conductor UL-listed range cord with closed-loop
terminals, open-end spade lugs with upturned ends
or similar termination. DO NOT install the power cord
without a strain relief.
A range cord rated at 40 amps with 120/240 minimum
volt range is required. If a 50 amp range cord is used, it
should be marked for use with 13⁄8” diameter connection
openings. This appliance may be connected by means
of conduit or power cord. If conduit is being used, go to
page 7 for 3 wire conduit connections or page 8 for 4
wire conduit connections.

• New branch-circuit installations (1996 NEC)

for mobile homes, recreational vehicles, and

installations where local codes do not allow

grounding through the neutral wire require

a 4-conductor UL listed range cord or 4 wire

conduit connection.

• Power supply cord and plug should not be

modified. If it will not fit the outlet, have a

• Using an extension cord to connect the power is

prohibited. The way to connect the power cord

and plug directly is strongly recommended.

• Electrical ground is required on this appliance.

• You should make sure that the power cord is

not pinched by the range or heavy objects.

- Failure to do so can result in serious burns or

electrical shock.

WARNING

Range rating, watts

rating of power
supply-cord kit,

amperes

Diameter (inches) of Range

connection Opening

120/240 volts

3-wire

120/208 volts

3-wire

Power cord

Conduit

8,750 - 16,500

16,501 - 22,500

7,801 - 12,500

12,501 - 18,500

40 or 50A

50

1

3

/

8

1

3

/

4

1

1

/

8

1

3

/

8

3, 4 - Wire electrical wall Receptacle

4 Wire receptacle (14-50R)

3 Wire receptacle (10-50R)

FIgURE 3

CONNECT RANGE CORD

The Rear Access cover must be removed. Loosen the
three screws with a screwdriver. The terminal block will
then be accessible.

FIgURE 4

Terminal block

Drawer body

Access

cover

Power cord outlet

Cord/Conduit

connection

plate

The Cord/Conduit connection plate is used for the
installation of power cord or conduit. For power cord,
install it with the connection plate as INSTALLED. For
conduit, remove the connection plate located below the
rear of the drawer body and use the conduit hole (1

1

/

8

”)

instead of power cord hole (1

3

/

8

” ). (Refer to Figure 5 and 6.)

1

3

/

8

"

(3.5cm)

1

3

/

8

"(Cord)

1

1

/

8

"(Conduit)

1

1

/

8

"

(2.8cm)

Remove the Conduit connection plate

FIgURE 5

FIgURE 6

Strain relief

Conduit

Assemble the

strain relief hole

Reinstall the Cord/Conduit connection plate

Ring

Cord Strain

relief

Conduit

Body

Cord/conduit

connection

plate