4f23, Architectural decorative, Features – Lightolier Architectural Decorative 4F23 User Manual
Page 2: Lamping (by others), Electrical, Mounting, Labels, Application data, Job information type
Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • D0609
Architectural Decorative
4F23
Page 2 of 2
Pendalux Gemini 23” Diameter Body 2-26/32/42 Triple Tube
Features
1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel, 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 3/4” steel tube. Canopy, 7” Dia.,
fastened internally, no exposed hardware. Permits installation on ceilings
with slope of up to 45˚. Complies with California Code.
5. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4
lamp base.
6. Flange Trim: Steel 20 gauge, Plated or Painted finish.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
General Electric
Osram/Sylvania
Philips
26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F26TBX/*/A/4P
CF26DT/E/IN/*
PL-T26W/*/4P
32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F32TBX/*/A/4P
CF32DT/E/IN/*
PL-T32W/*/4P
42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp
F42QBK/*/A/4P
CF42DT/E/IN/*
PL-T42W/*/4P
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
N120/277V, Multi-Wattage 26/32/42W.
4 Lamp
26 Watt
32Watt
42Watt
Voltage
120V 277V 120V 277V 120V 277V
Total Input Watts
55
55
68
68
93
93
Max. Line Current (amps) 2.22
0.96 2.80
1.20 1.20
1.60
Power Factor
>0.98 >0.98 >0.98 >0.98 >0.99 >0.99
Ballast Factor
1.02
1.02 0.96
0.96 0.95
0.95
THD<10% Minimum Starting Temperature: -5°F/-20°C.
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus listed (suitable for damp locations).
Application Data
Reflectances: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75(.88 BF x .85)
FC (footcandles) at 30” work plane.
ZONAL LUMENS AND PERCENTAGES
DATE: OCT. 4, 2000
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA
ANGLE MEAN CP LUMENS
0
195
5
193
18
10
191
15
189
53
20
184
25
177
82
30
169
35
158
99
40
148
45
137
106
50
126
55
113
101
60
100
65
88
87
70
76
75
64
68
80
53
85
42
47
90
38
CERTIFIED TEST REPORT NO. 4A23242A
COMPUTED BY LSI PROGRAM **TEST-LITE**
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4A23242, 23” DIFFUSER
2-42W T/E SYLVANIA LAMPS. LUMEN RATING = 3200 LMS.
ADVANCE BALLAST #ICF-2S42-M2-LD, 120VAC
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
ANGLE MEAN CP LUMENS
90
38
95
80
121
100
245
105
437
456
110
604
115
735
725
120
848
125
949
848
130
1035
135
1091
842
140
1133
145
1140
713
150
1125
155
1103
507
160
1051
165
956
267
170
812
175
647
65
180
598
C
ANDLEPOWER SUMMARY
DATE: DEC. 11, 2000
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80
70
50
30
10
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1
.69 .66 .63 .60 .58 .55 .44 .43 .41 .29 .28 .27 .15 .15 .15 .08
2
.60 .55 .51 .53 .49 .45 .38 .36 .34 .25 .24 .23 .13 .13 .12 .07
3
.53 .47 .43 .46 .42 .38 .34 .31 .28 .22 .21 .19 .12 .11 .10 .06
4
.47 .41 .36 .41 .36 .32 .30 .27 .24 .20 .18 .16 .11 .10 .09 .05
5
.41 .35 .30 .36 .31 .27 .27 .23 .20 .18 .16 .14 .09 .08 .08 .04
6
.37 .31 .26 .32 .27 .23 .24 .20 .18 .16 .14 .12 .08 .07 .07 .04
7
.33 .27 .22 .29 .24 .20 .21 .18 .15 .14 .12 .10 .08 .06 .06 .03
8
.30 .24 .20 .26 .21 .17 .19 .16 .13 .13 .11 .09 .07 .06 .05 .03
9
.27 .21 .17 .23 .19 .15 .17 .14 .12 .12 .10 .08 .06 .05 .04 .02
10
.24 .19 .15 .21 .17 .13 .16 .13 .10 .11 .08 .07 .06 .05 .04 .02
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
153
2.40
2.95
0-40
252
3.95
4.86
0-60
459
7.18
8.83
0-90
661
10.34
12.72
40-90
409
6.39
7.86
60-90
202
3.16
3.88
90-180
4543
70.98
87.28
0-180
5204
81.33
100.00
** EFFICIENCY = 81.3% **
23 Inch Diameter
24’ x 24’ x 9.5’ Space
Luminaire
Spacing: 8’ x 8’
Susp. Dist. 24”
2 Lamps
26W
32W
42W
TTT
TTT
TTT
Illum. (FC)
22
29
40
Maint.
Lum.
7/1
7/1
8/1
Ratio
Watts/
0.85
1.06
1.45
Sq. Ft.