12
Carafe or Mug not detected (flashing brew light)
•
IRD cannot detect flat black or clear glass mug (change mug color)
•
IRD window is dirty (wipe with moist towel and dry)
•
Mug not close enough to IRD (move farther into brewer)
•
IRD is not set properly, call for technical service.
Water dripping from spray head
•
Spray head plugged (replace or clean spray head)
•
Normally, some water will drip from the spray head shortly after brewing
•
Slight valve leak (debris inside valve, disconnect water and reconnect, run 1-2 full cycles of water in carafe to
dislodge debris and check)
•
Valve leak permanent, call for technical service.
Water dripping down walls of carafe area
•
Spray head plugged (replace or clean spray head)
•
Spray head leak around threads, (remove spray head, clean and re-install for tight fit)
Coffee not staying warm
•
Possible carafe vacuum failure (if carafe is warm to touch, replace carafe)
•
Preheat carafe before brewing coffee especially if used for half pot. (run brew cycle without filter or coffee)
•
Check volume of water by running a full cycle of water without coffee. If carafe overfills call for technical service.
Water leak from back of brewer
•
Check quick connect (push connectors together firmly and slightly twist)
•
Poly line leak at brewer, call installer to repair.
•
Valve connection leak, call for technical service.
trOUBleshOOtinG
parts & serviCe
Spare parts are available from Lance Larkin™ (866) 268-5953 or email [email protected].
Contact Lance Larkin™ for all service and warranty issues.
• Spray head
•
Brew Basket(s)
•
Carafe and lid
•
Mounting screws
•
Auxiliary water pump and (5) gallon jug.
For installation in areas without water supply.