beautypg.com

Wiring diagrams, N o t e, Attaching wires – Lux Products TX9000 User Manual

Page 2

background image

Attaching Wires

4.Hold the base against the wall, with the wires

coming through wherever it is convenient for wiring.

Route the wires to below the terminal block. Position

the base for best appearance (to hide any marks

from an old thermostat). An optional wall plate is

included for covering old mounting holes. Attach the

base to the wall with the two screws provided.

REMOVING THE OLD THERMOSTAT

Switch electricity to the furnace and air
conditioner OFF; then proceed with the
following steps.
1. Remove cover from old thermostat. Most

are snap-on types and simply pull off.
Some have locking screws on the side.
These must be loosened.

2. Note the letters printed near the terminals.

Attach labels (enclosed) to each wire for
identification. Remove and label wires one
at a time. Make sure the wires do not fall
back inside the wall.

3. Loosen all screws on the old thermostat

and remove it from the wall.

MOUNTING THE UNIT ON THE WALL

1. Strip insulation 3/8 in. (9.5mm) from wire ends and clean off any corrosion.
2. Fill wall opening with non-combustible insulation to prevent drafts from

affecting the thermostat.

3. Press up on the button on bottom of

thermostat and swing the body away
from the base and up to remove the
body from the base.

C A U T I O N

Read instructions carefully

before removing any wiring

from existing thermostat.

Wires must be labeled before

they are removed. When

removing wires from their

terminals, ignore the color of

the wires since these may not

comply with the standard.

C

A

U

T

I

O

N

Be careful not to drop the body or disturb electronic parts.

Leave the cover closed while the body is being removed from the base.

TERMINALS

SCREW
ANCHORS

BASE

W3

L

R

G

O

G Y W RH B

O RC

C

A

U

T

I

O

N

Do not allow wires to touch each other or parts on

thermostat. Wires must be trapped between black spacer

and brass terminal. Also, be sure to tighten securely all 7

electrical terminal screws.

N O T E

If you are mounting the base to a soft material like plasterboard

or if you are using the old mounting holes, the screws may not

hold. Drill a 3/16-in. (4.8mm) hole at each screw location, and

insert the plastic anchors provided. Then mount the base as

described below.

WIRING DIAGRAMS

HEATING ONLY SYSTEMS

COOLING ONLY SYSTEMS

4 -WIRES WITH ONE TRANSFORMER

5 -WIRES WITH TWO TRANSFORMERS

HEATING / COOLING SYSTEMS

HEATING / COOLING SYSTEMS

Y

O

G

W

B

RH RC

OPTIONAL F

AN WIRE

RC-RH JUMPER

PROVIDED

RH

RC

R

V

5

G

F

W

H

4

Y

O

G

W

B

RH RC

RC-RH JUMPER

PROVIDED

RH

RC

G

F

R

V

5

Y

C*

6

Y

O

G

W

B

RH RC

RC-RH JUMPER

PROVIDED

RH

RC

R

V

5

V

5

W

H

4

Y

C*

6

G

F

Y

O

G

W

B

RH RC

RC-RH JUMPER

PROVIDED

*CUSTOMER

SUPPLIED

JUMPER

RH

RC

R

Y

C*

G

F

Y

O

G

W

B

RH RC

RC-RH JUMPER

REMOVED

RH

V

5

TYPICAL SINGLE STAGE

HEAT PUMP WIRING

W

H

4

Y

C*

6

G

F

RC

R

O

B

USE B or O NOT BOTH

WIRING DIAGRAM NOTES
(APPLIES TO ALL DRAWINGS)
• The DASHED lines are optional
depending upon your system type.

• Verify whether “C”, “X” or “B” wires
are connected to system common.

• If “B” and “O” are both present, it is
likely that “B” is a system common.

• If a “B” wire in your system is a
common, then connecting it to the
“B” terminal may cause damage to
your system.

• If “Y” and “C” are both present, it is
likely that “C” is a system common.

These diagrams below are provided for new installations or

unreferenced wires.

TYPICAL HOOKUP FOR 2 OR 3 WIRE

24 VAC HEATING SYSTEMS (AND MILLIVOLT)

Y

O

G

W

B

RH RC

Gas

Valve

or

Heater

FAN

System

XFMR

RH-RC JUMPER

PROVIDED

OPTIONAL

FAN LEAD

COMMON

TYPICAL COOL HOOKUP

24 VAC SYSTEMS

Y

O

G

W

B

RH RC

FAN

A/C

Comp.

System

XFMR

RH-RC JUMPER

PROVIDED

SYSTEM

COMMON

2