11 f, Led indicators – LevelOne FPS-2013TXU User Manual
Page 14
Introduction
LED Indicators
All LevelOne Printer Servers are fitted with 2 LED indicators. The red LED is the
Status/Error indicator. The green LED is the Power/Link indicator. The LED indicator
modes are described in the following table.
Green LED
Red/Orange LED
Status Description
Off Off
No
power.
On On
Hardware
error.
Flashing
Flashing
Firmware upgrade in progress.
On
Flashing (USB only)
No printer connected to the USB port.
On
Off
Normal operation - idle.
Flashing
Off
Normal operation - transmitting or
receiving packets from the network.
DIP Switches - FPS-2101TXU & FPS-2003TXU
The DIP switches are used to set the LAN connection. Operation is as follows.
SW1
SW2
SW3
Description
UP
UP
UP
Auto select LAN connection (Default)
UP
UP
Down
Use BNC connector
Down Down
Down
10BaseT - Half Duplex
Down Down
UP
10BaseT - Full Duplex
Down UP
Down
100BaseT - Half Duplex
Down UP
UP
100BaseT - Full Duplex
The other possibilities are reserved, and should not be used.
DIP Switches - FPS-2111TXU & FPS-2013TXU
The DIP switches are used to set the LAN connection. Operation is as follows.
SW1
SW2
SW3
Description
UP
-
-
Auto select LAN connection (Default)
Switches 2 and 3 have no effect.
Down Down
Down
10BaseT - Half Duplex
Down Down
UP
10BaseT - Full Duplex
Down UP
Down
100BaseT - Half Duplex
Down UP
UP
100BaseT - Full Duplex
The other possibilities are reserved, and should not be used.
- 11 -