Liebert Integrated Secured Protection User Manual
Page 2

2
SAFETY INSTRUCTIONS ................................................................................................................................... 3
GLOSSARY OF SYMBOLS................................................................................................................................. 3
INTRODUCTION ................................................................................................................................................. 4
UPS SUPPORT................................................................................................................................................ 5
INSTALLATION................................................................................................................................................... 5
UNLOADING AND INSPECTION ..................................................................................................................... 5
LOCATION....................................................................................................................................................... 5
INSTALLATION CONNECTIONS ..................................................................................................................... 6
INSTALLING CUSTOMER EQUIPMENT.......................................................................................................... 6
START-UP ....................................................................................................................................................... 7
OPERATION ....................................................................................................................................................... 8
ENVIRONMENTAL CONTROL MODULE (ECM) & UNINTERRUPTIBLE AIR SUPPLY™ (UAS)...................... 8
FORCED AIR COOLING (FAC)........................................................................................................................ 8
SITENET® INTEGRATOR® ............................................................................................................................. 8
SENSOR OPTIONS ......................................................................................................................................... 9
MAINTENANCE ................................................................................................................................................ 10
FILTER CLEANING........................................................................................................................................ 10
ECM REPLACEMENT.................................................................................................................................... 10
UPS REPLACEMENT .................................................................................................................................... 10
TABLES ............................................................................................................................................................ 11
FORCED AIR COOLING (FAC) PERFORMANCE DATA (WITH 30PPI FILTER) ............................................ 11
ENVIRONMENTAL COOLING MODULE (ECM) PERFORMANCE DATA....................................................... 11
FIXED SERVICE CONNECTION (AMPS)....................................................................................................... 12
MAX. AVAILABLE CUSTOMER EQUIPMENT AMPS ..................................................................................... 12
FULL LOAD AMP DRAW (230V - 50H
Z
) ......................................................................................................... 12
DRAWINGS....................................................................................................................................................... 13
TROUBLESHOOTING....................................................................................................................................... 23
Model Number Breakdown
RD
78 38
M
D
E
K
Enclosure
Rack Width
Enclosure
Height/ Depth
Main or
Cluster
Primary Cooling
System
UPS
Rack-Mount
Input Power
RD=24" Rack
HD=19" Rack
78" Height
72" Height
38" Depth
34" Depth
(Nominal)
M = Main
C = Cluster
A = FAC-190
B = FAC-360
C = ECM-42
D = ECM-62
E = N/A
F = ECM-80
0 = None
A = N/A
B = N/A
C = GXT-1000
D = N/A
E = GXT-1500
F = N/A
G = GXT-2000
K = 120V/60Hz/1PH
S = 230V/50Hz/1PH